WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT,
DOUBLE-HUNG FRAME USING FRAME SCREWS
These instructions were tested and developed for replacing windows in
Installation recommendations for other types of wall construction, wall systems or conditions may be obtained from Pella Corporation or a local Pella retailer. Building designs, construction methods, building materials, and site conditions unique to your project may require an installation method different from these instructions and additional care on your part. Determining the appropriate installation method is the responsibility of you, your architect, or other construction professional.
YOU WILL NEED TO SUPPLY:
•Cedar or Impervious shims/spacers (12 to 20)
•Closed cell foam backer rod/sealant backer
(12 to 30 ft.)
• Pella® SmartFlash™ foil backed butyl window
and door flashing tape or equivalent
•Pella Window and Door Installation Sealant or equivalent high quality,
(1 tube per window) SEALANT
•Low expansion, low pressure polyurethane insulating window and door foam sealant - DO
NOT use high pressure or latex foams
•#8 x
•Pella replacement window sill adapter
Installation will require two or more persons for safety reasons.
REMEMBER TO USE APPROPRIATE
PERSONAL PROTECTIVE EQUIPMENT
CAUTION: Many windows in older homes are painted with
TOOLS REQUIRED:
• Tape measure
• Level
• Sealant gun
•Prybar
•Utility knife
• Putty knife
• Hammer
• Screwdrivers (Flat & Phillips)
• Adjustable pliers
• Side Cuts
•
• Wood chisel
• 1/8" drill bit
• Drill
Sill Adapter
Flashing Tape
Always read the Pella® Limited Warranty before purchasing or installing Pella products. By installing this product, you are acknowledging that this Limited Warranty is part of the terms of the sale. Failure to comply with all Pella installation and maintenance instructions may void your Pella product warranty. See Limited Warranty for complete details at http://warranty.pella.com.