IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS.
Basic safety precautions should always be followed when operating and servicing this electrical equipment.
WARNING : To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
SAVE THESE INSTRUCTIONS.
SAFETY FEATURES
HEATER PROTECTION :
A
This feature enables the heater to cool down, so that the heat exchanger and plumbing are not damaged from overheating.
For testing and servicing purposes, it is possible to override this delay circuit b y pushing the DELAY CANCEL Button at the
POOL CLEANER PROTECTION :
If your system incorporates an automatic pool cleaner, it will have been plumbed in conjunction with the filter pump so that it must have water circulation in order to operate. The
1.Your pool cleaner will automatically be switched off whenever water is being circulated to the Spa.
2.The filter pump will automatically be activated whenever the pool cleaner is running. even if the filter pump has not been switched on.
3.Additionally, whenever the pool cleaner is turned on: a
For testing and servicing purposes, it is possible to override this delay circuit b y pushing the DELAY CANCEL Button at the
4.If your system incorporates solar, the pool cleaner will automatically be disabled for a period of 4 minutes whenever the solar system turns on. This protects the pool cleaner from possible damage caused by residual air within the solar panels.
BATTERY BACK-UP :
In case of a power failure, a
MAINTENANCE
REPLACING THE BACK-UP BATTERY :
There is a small 3 volt lithium battery located on the backside of the
While power is connected to the system, the battery will not be dra~ned. However. it is not rechargeable.
To replace the battery :
1.Remove the four mounting screws from
2Carefully fold Controller out, still connected to cable.
3.
The Replacement battery is available directly from Compool (model
CLEANING THE SPA :
For cleaning or maintenance purposes, it is possible to use the Control System to automatically empty your spa and then to refill with clean water from your pool.
At the
1.Set SYSTEM CONTROL Switch to the "SERVICE position.
2.Set FLOW CONTROL Switch to the "DRAIN'position.
3.At the MANUAL CONTROL, set FILTER Switch to the "ON" position.
4. The spa will begin to drain into the pool. Do not drain completely, or prime will be lost. CAUTION: Do not leave equipment unattended when draining or filling the spa.
5.When cleaning is complete. set FLOW CONTROL Switch to the FILL" position. The spa will begin to fill with clean water from the pool.
6.When the spa water level has returned to normal, return FLOW CONTROL Switch to the "POOL" position, FILTER Switch at the MANUAL CONTROL to the "OFF" position, and SYSTEM CONTROL Switch to the "AUTO" position.
WINTERIZING THE SYSTEM :
During the winter season, it is possible to drain your pool and disable the pool equipment from your control system. but still be able to use your spa. Consult a qualified service company to drain your pool and protect the plumbing from freeze damage.
The following procedure will disable the pool equipment :
1.At the
2.Unplug cables from Valve Operators.
3.At the
SYSTEM CONTROL Switch to the "AUTO" position.
4 . At the electrical supply panel, turn off the pool cleaner circuit breaker.
5.At the
6.If your control system incorporates solar, ensure that the panels are completely drained. and, at the
If your system is equipped with Recirculating Freeze Sensors, it may not be necessary to drain the pool. However, it is recommended that all Freeze Sensors be tested b y an authorized Serviceperson before the onset of the winter season.