CUSTOM CLOCK OPTIONS
The standard
Your Pool Builder may, however, have incorporated one or more of the following custom features :
COUNTDOWN TIMER :
This feature enables you to preset a 10 minute operating cycle for any piece of equipment (FILTER, CLNR, SPA or AUX1).
Whenever that equipment is activated, it will run for 10 minutes and then it will automatically switch off.
SERVICE CENTER
Located in close proximity to your pool and spa equipment. the
CAUTION: To prevent possible water damage, the door of the
Equipment Service Switches are located in the
There are no
To better understand this feature, let us look at a typical application : |
| |||
For example, we are using the AUXl circuit to activate a spa jet pump, and we would like | . | |||
the jets to run for a period of 10 minutes whenever they are activated. | ||||
Push PROGRAM Button to put Clock into | I |
|
| |
Program Mode. |
|
| ||
"PROG will appear on the right of the Display. | TIME CONTROL |
| ||
|
|
|
| |
Continue to push PROGRAM E3utton until a |
|
|
|
|
flashing "TIMER' appears. |
|
|
|
|
Push the MINUTES h t t o n once. | OFF | OFF | OFF |
|
"0:10'will appear on the Display. |
| |||
|
|
|
| |
Push appropriate Equipment h t t o n (AUX 1 in | W E l | C U | SPA AUXI |
|
|
|
|
| |
our example). |
|
|
|
|
"ON" will appear directly above Equipment |
|
|
|
|
Button |
|
|
|
|
Push PROGRAM Button to |
|
|
|
|
ADDITIONAL AUXILIARY CONTROL : |
|
|
|
|
If your Control System does not utilize a pool cleaner, your Pool Builder may have |
| |||
overridden the |
| |||
Button can be used to activate an additional auxiliary function (such as landscape |
|
SYSTEM CONTROL :
This Switch should be kept in the "AUTO" position for normal system operation.
The "SERVICE" position will disable the
MANUAL CONTROL :
Separate Service Switches are provided for activating the filter pump, pool cleaner, and auxiliary 1 circuit (lights, jet pump, etc.).
However, the SYSTEM CONTROL Switch must be in the "SERVICE"position before these Switches can be turned ON.
Note: Always return MANUAL CONTROL Switches to the 'OFFposition after equipment has been serviced.
..,I", "0 1 1 1 1 , P I
S Y S T E M CONTROL
I W I I C " M Y I S I/I" | I I R " C l .OII1I"* | 3" | |
0 , l S A l l ,,o1co*,.01 | .*D | *.I".L"*IIDL, | l. I l l t 5 |
tOUlPMEN1 UNDER COMPUTER CONTROL
EOUIPMENT UNDER
M A N U A L C O N l P O l
B, 8" | ,,.",<,PO, | I,*" |
I,,,,,, | < O * I S Y L | *",I |
lighting). | I | * | |
In this instance, the equipment will turn on | T l M E CONTROL | ||
immediately (no 4 minute ON delay), and the | |||
|
| ||
filter pump will not be simultaneously |
|
| |
activated. |
|
| |
| CTr1.n | C L M SPA AUX1 |
\
PROGRAM LOCK :
To safeguard against someone accidentally pushing the PROGRAM h t t o n and inadvertently tampering with your daily program, your Pool Builder may have included a Program Lock feature.
In this instance, you will need to push the PROGRAM Button quickly twice in order to put the Clock into Program Mode.
FLOW CONTROL :
To enable this Switch, the SYSTEM CONTROL Switch must be in the "SERVICE"position.
The "POOL and "SPA positions will automatically rotate the motorized valves to the appropriate water circulation.
The "FILL and "DRAIN" positions are used when cleaning the spa. (See page 16).
Note: It is advisable to return FLOW CONTROL Switch to 'POOL'position after use.
SOLAR CONTROL :
This Switch should be kept in the "AUTO" position for normal system operation.
The "OFF and "ON" positions provide
OUTDOOR REMOTES :
This Switch should be kept in the "ON'position for normal system operation.
The "OFF" position will disable any optional Remote Controls which may have been added to your system.
This feature is particularly convenient if your system includes a