CUSTOM CLOCK OPTIONS

CUSTOM CLOCK OPTIONS

The standard CP-2000 Controller is provided with the appropr~ateequipment interlock and safety delays, and enables you to enter a total of six program steps.

Your Pool Builder may, however, have incorporated one or more of the following custom features :

COUNTDOWN TIMER :

This feature enables you to preset a 10 minute operating cycle for any piece of equipment (FILTER, CLNR, SPA or AUX1).

Whenever that equipment is activated, it will run for 10 minutes and then it will automatically switch off.

SERVICE CENTER

Located in close proximity to your pool and spa equipment. the LX-10 SERVICE CENTER provides your Pool Serviceperson with manual control of the system without having to gain access to the CP-2000 Controller.

CAUTION: To prevent possible water damage, the door of the U(-10 must be kept closed at all times.

Equipment Service Switches are located in the left-side compartment.

There are no user-serviceable components located behind service panel in the right-side compartment. Do not remove service panel. Refer service to qualified personnel only.

To better understand this feature, let us look at a typical application :

 

For example, we are using the AUXl circuit to activate a spa jet pump, and we would like

.

the jets to run for a period of 10 minutes whenever they are activated.

Push PROGRAM Button to put Clock into

I

 

 

Program Mode.

 

 

"PROG will appear on the right of the Display.

TIME CONTROL

 

 

 

 

 

Continue to push PROGRAM E3utton until a

 

 

 

 

flashing "TIMER' appears.

 

 

 

 

Push the MINUTES h t t o n once.

OFF

OFF

OFF

 

"0:10'will appear on the Display.

 

 

 

 

 

Push appropriate Equipment h t t o n (AUX 1 in

W E l

C U

SPA AUXI

 

 

 

 

 

our example).

 

 

 

 

"ON" will appear directly above Equipment

 

 

 

 

Button

 

 

 

 

Push PROGRAM Button to lock-in the program

 

 

 

 

ADDITIONAL AUXILIARY CONTROL :

 

 

 

 

If your Control System does not utilize a pool cleaner, your Pool Builder may have

 

overridden the built-in Pool Cleaner Protection Circuits, so that the CLNR Equipment

 

Button can be used to activate an additional auxiliary function (such as landscape

 

SYSTEM CONTROL :

This Switch should be kept in the "AUTO" position for normal system operation.

The "SERVICE" position will disable the CP-2000 Controller and provide your Pool Serviceperson with complete manual-override capability of all pool equipment.

MANUAL CONTROL :

Separate Service Switches are provided for activating the filter pump, pool cleaner, and auxiliary 1 circuit (lights, jet pump, etc.).

However, the SYSTEM CONTROL Switch must be in the "SERVICE"position before these Switches can be turned ON.

Note: Always return MANUAL CONTROL Switches to the 'OFFposition after equipment has been serviced.

..,I", "0 1 1 1 1 , P I

S Y S T E M CONTROL

I W I I C " M Y I S I/I"

I I R " C l .OII1I"*

3"

0 , l S A l l ,,o1co*,.01

.*D

*.I".L"*IIDL,

l. I l l t 5

tOUlPMEN1 UNDER COMPUTER CONTROL

EOUIPMENT UNDER

M A N U A L C O N l P O l

B, 8"

,,.",<,PO,

I,*"

I,,,,,,

< O * I S Y L

*",I

lighting).

I

*

In this instance, the equipment will turn on

T l M E CONTROL

immediately (no 4 minute ON delay), and the

 

 

filter pump will not be simultaneously

 

 

activated.

 

 

 

CTr1.n

C L M SPA AUX1

\

PROGRAM LOCK :

To safeguard against someone accidentally pushing the PROGRAM h t t o n and inadvertently tampering with your daily program, your Pool Builder may have included a Program Lock feature.

In this instance, you will need to push the PROGRAM Button quickly twice in order to put the Clock into Program Mode.

FLOW CONTROL :

To enable this Switch, the SYSTEM CONTROL Switch must be in the "SERVICE"position.

The "POOL and "SPA positions will automatically rotate the motorized valves to the appropriate water circulation.

The "FILL and "DRAIN" positions are used when cleaning the spa. (See page 16).

Note: It is advisable to return FLOW CONTROL Switch to 'POOL'position after use.

SOLAR CONTROL :

This Switch should be kept in the "AUTO" position for normal system operation.

The "OFF and "ON" positions provide manual-override of your solar system, and should be used for servicing and testing purposes only.

OUTDOOR REMOTES :

This Switch should be kept in the "ON'position for normal system operation.

The "OFF" position will disable any optional Remote Controls which may have been added to your system.

This feature is particularly convenient if your system includes a Spa-side Remote Control, and you wish to prevent the unauthorized use of your spa while you are away from home.