PROGRAMMING INSTRUCTIONS

The CP-2000 Controller houses a 24 hour Clock with a digital display, which can be used to program daily pool filtration, cleaning, and other auxiliary functions such as pool and spa lights. It can also be used to program and preheat your spa. so that it is ready for use when you arrive home.

The Clock has two operating modes:

1.TlME MODE :

In Time Mode (normal operation), the Clock will display the actual time of day, and "TIME' willappear on the right of the Display.

While the Clock is in Time Mode, the pool equipment can be manually activated by simply pushing the appropriate Equipment Button (FILTER, CLNR, SPA or AUXI). This will temporarily override any preset program which may be in effect.

2.PROGRAM MODE :

In order to preselect daily filtration cycles, pool cleaning, spa use, and an auxiliary function (such as spa light), the Clock must be switched to Program Mode.

To achieve this, push PROGRAM Button once.

Whenever Clock is in Program Mode, "PROG will appear on the right of the Display. After programming is complete, the Clock will automatically return to Time Mode.

SETTING THE CLOCK

If the Clock is not already in Time Mode, push PROGRAM Button until "TIME appears on

 

the right of the Display.

 

1

This indicates that the Clock is in Time Mode.

 

Push the HOURS and MINUTES Buttons until

A

the correct time of day is displayed

Pay special attention to the AM/PM indicator.

PROGRAMMING DAILY OPERATING CYCLES :

Programming the daily operating cycles of your pool equipment is a "set and forget" procedure, which is normally implemented by your Pool Builder at the completion of the installation.

Most systems only require that you program the filtration and (in some cases) the cleaning cycles of the pool. However, it is possible to program the spa (if you plan to use it at the same time every day), and also AUXl (if you are using this circuit to activate lights or some other equipment which you wish to operate at the same times every day).

It is possible to preset six program steps during a 24 hour period. Each of the six steps can be used for turning equipment ON or OFF.

More than one piece of equipment can be turned ON or OFF at each program step. However, to turn the same piece of equipment ON and OFF requires two program steps Once the programming is complete, the pool and spa equipment will operate at the same times every day.

Before commencing programming, it is advisable to determine at what time you would like the equipment to turn on, and for how long you would like each piece of equipment to run.

To better understand the programming sequence, let's followa sample program, step by step. For demonstration purposes, our example assumes that we would like to activate all four pieces of equipment on a daily basis, as follows :

Filter the pool from 7:00 am until 12:00 pm.

Turn the pool cleaner on from 10:00 am until 12:00 pm. Turn the spa on from 6:30 p m until 8:00 pm.

Turn auxiliary 1 (spa light) on from 6:30 p m to 10:00 pm.

To begin programming, push PROGRAM Button once.

"PROG 1" will appear on the right of the Display. This indicates that the Clock is in

Program Mode, and that the first oroaram step is readv to be entered.

'

~ n t ether first program time (7:00'aminour

example) by pushing the HOURS and

#

 

b

TlME CONTROL

MINUTES Buttons.

 

 

PROGRAM

In Program Mode, minutes are advanced in

7.)-4)-4AMPRffi

:

ten minute increments.

Push FILTER Equipment Button.

OFF

OFF

 

" O N should appear directly above FILTER

 

 

 

 

Button.

 

 

 

If "ON" is displayed above any of the other

 

 

 

EQUIPMENT Buttons, push appropriate Button

 

 

 

once, and "OFF'will appear.

 

 

t

You have now completed the first program step.

 

 

 

In order to lock-in the program, simply push the PROGRAM Button once

"PROG 2" will now appear on the right of the Display. This indicates that the second

program step is ready to be entered.

#

 

9

Enter the second program time (10:OO am) by

 

TlME CONTROL

pushing the HOURS and MINUTES Buttons.

 

 

PRO-A"

Push CLNR Equipment Button.

 

 

 

" O N should appear directly above CLNR

 

 

 

Button.

 

 

 

In our example, at 10:OO am the filter pump

 

 

 

should still be running. However, it will not be

RLTIR C U M

SPA

AUX1

 

necessary to push the FILTER Equipment

 

 

 

M o n , because the built-in protection circuit

4

 

 

will automatically activate the filter pump

 

I

whenever the pool cleaner is on.

Make sure that "OFF'is still displayed above SPA and AUXl Equipment Buttons. Push PROGRAM Button to lock-in the program.

Page 7
Image 7
Pentair CP-2000 warranty Programming Instructions, TlME Mode

CP-2000 specifications

The Pentair CP-2000 is an advanced water purification system designed to deliver high-quality drinking water for both residential and commercial applications. With its state-of-the-art technologies, the CP-2000 offers an innovative solution to meet the demand for clean and safe water. This system is especially recognized for its efficiency and effectiveness in removing various contaminants from water sources.

One of the standout features of the Pentair CP-2000 is its multi-stage filtration process. The system incorporates a series of filters that work in tandem to effectively reduce sediments, chlorine, heavy metals, and other harmful substances. Each stage of filtration is carefully engineered to ensure optimal purification, producing fresh and great-tasting water.

The CP-2000 utilizes advanced reverse osmosis technology, which is a hallmark of its purification capabilities. This method involves forcing water through a semi-permeable membrane, allowing only clean water to pass through while blocking contaminants. The result is water that is significantly purer than standard tap water. Additionally, the system also features a post-carbon filter that further polishes the water, enhancing taste and odor.

Another key characteristic of the CP-2000 is its user-friendly design. The system is equipped with a digital display that provides real-time information on filter life and system performance. This ensures users can stay informed about their water quality and allows for timely maintenance. The CP-2000 also includes an automatic shut-off feature that helps conserve water when the system is not in use.

In terms of installation, the Pentair CP-2000 is compact and designed for ease of integration into existing plumbing systems. Its modular design allows for straightforward replacement of filter components, making maintenance hassle-free. This attribute is particularly beneficial for users who may not have extensive technical knowledge.

The energy-efficient operation of the CP-2000 is another noteworthy aspect. By minimizing power consumption, this system not only supports sustainability goals but also contributes to lower utility bills. Pentair has engineered the CP-2000 to function quietly, ensuring that it operates without disrupting daily activities.

Overall, the Pentair CP-2000 represents a significant advancement in water purification technology. With its robust filtration capabilities, ease of use, and energy efficiency, it stands out as a reliable solution for those seeking to enhance their water quality. Whether for home or business, the CP-2000 is dedicated to delivering exceptional performance, ensuring access to clean and safe drinking water.