Pentair DP233110V owner manual Maintenance, Troubleshooting, Switch Replacement

Models: DP233110V

1 24
Download 24 pages 58.98 Kb
Page 6
Image 6
Maintenance

Maintenance

6

Switch Replacement

Switch ReplacementTROUBLESHOOTINGManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Risk of electric shock. When servicing pump, always disconnect power to electrical outlet and remove pump electric cord from outlet.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Float must be able to complete its entire cycle without interference from sidewall of basin, plumb- ing, or any other object.

1.Mount bracket on switch housing using existing screws.

2.Slide rod into slot in bottom of switch housing. Fasten rod into switch housing with pin.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Make sure pin holds float rod in switch housing; otherwise pump will not shut off.

NOTE: Pull gently on rod to make sure that it cannot come out of switch housing.

3.Mount switch assembly on pump using existing screws. Make sure that nothing interferes with switch operation.

4.Mount float on rod.

5.Install rod stop on bottom of rod.

6.Run pump through one complete cycle to verify cor- rect switch operation.

Manual background Risk of flooding. Drainer Pre-Plumbed System comes with the automatic float switch mounted on the motor housing ready for operation. Do not change switch settings. Switch is set to start at approximately 6.5" and to stop at approximately 2".

TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t

1.

Blown fuse.

1.

If blown, replace with fuse of proper size.

start or run.

2.

Low line voltage.

2.

If voltage under recommended minimum,

 

 

 

 

check size of wiring from main switch on

 

 

 

 

property. If OK, contact power company or

 

 

 

 

hydro authority.

 

 

 

 

 

Pump won’t

1.

Restricted discharge

1.

Remove obstacle in piping.

shut off.

 

(obstacle in piping).

 

 

 

 

 

 

 

Pump operates

1.

Restricted discharge

1.

Remove obstacle in piping.

but delivers

 

(obstacle in piping).

 

 

little or no water.

 

 

 

 

 

 

 

 

 

Page 6
Image 6
Pentair DP233110V owner manual Maintenance, Troubleshooting, Switch Replacement