Image 26
Dimensional Data

20

Dimensional Data

Ø .500 MOUNTING HOLES

3.50

DIM B.

DIM A.

14.0 MAX.

12.3

4" STD FLANGE 1

16.35 +– .13.01

1 2

 

8 X 5/8-11 X 1" DP

FOR 6" STD FLANGE

5.75+– .06.00

.50

DIM C.+– .05.05

10.60

5.94 REF. 3

2FASTENERS AND O-RING ARE INCLUDED WITH PENTAIR POOL PRODUCTS EQ 6 X 6 STRAINER TO CONNECT STRAINER DIRECTLY TO EQ SERIES PUMP. IF PUMP IS TO BE INSTALLED WITHOUT STRAINER, MAKE BOTH CONNECTIONS PER NOTE 1.

1USE ANSI CLASS 150 PLASTIC FLANGE

AND 1/8" THICK CLASS 150 FULL FLANGE GASKET TO MAKE CONNECTION.

3THIS DIAMETER FITS INSIDE 6" SCH 40 PIPE. DO NOT USE SCH 80 PIPE AS FINAL PIPE

SIZE WHEN MAKING THIS FLANGE CONNECTION.

See, SECTION 9. PUMP TECHNICAL

DATA

“Engineering Specifications”

on page 19, for pump dimensions.

Ø .500 MOUNTING HOLES

3.50

DIM B.

20 ± .05

DIM D.

14" STD FLANGE

2FASTENERS AND O-RING ARE INCLUDED WITH PENTAIR POOL PRODUCTS EQ 6 X 6 STRAINER TO CONNECT STRAINER DIRECTLY TO EQ SERIES PUMP. IF PUMP IS TO BE INSTALLED WITHOUT STRAINER, MAKE BOTH CONNECTIONS PER NOTE 1.

1USE ANSI CLASS 150 PLASTIC FLANGE

AND 1/8" THICK CLASS 150 FULL FLANGE GASKET TO MAKE CONNECTION.

19.00

1 6" STD FLANGE

21.5

16.35+– .13.01

11.62 +– .09.03

DIM C. +– .05.05

ALL DIMENSIONS ARE IN INCHES.

EQ Series Pump Installation and User’s Guide

Page 26
Image 26