3. Checking RPM - (cont.)

1.Clean the Screen located inside the Wall Fitting. A small amount of debris will significantly affect the performance of the cleaner.

2.Clean the skimmer basket, pump basket and pool filter.

3.If an adjustable Gate (3-way) Valve has been installed, adjust the valve to increase water flow to the Legend® II.

4.If the RPM is more than 32, at the Wall Fitting, unscrew the Pressure Relief Valve slowly until the RPM falls between 25-32. Again, if an adjustable gate (3-way) valve has been installed, adjust the gate valve to decrease water flow to the Legend® II.

5.If you continue to have problems with either the water flow or obtaining the specified water

pressure to operate the Legend® II, call your

Professional Pool Dealer.If you have any additional questions, please contact Pentair Water Pool and Spa, Inc.,

Technical Support Department at:

1-800-831-7133, Monday through Friday.