Operating the Controller
An advanced microprocessor based controller that provides a sophisticated yet simple interface to operate your heat pump for maximum efficiency and enjoyment of your pool, controls the ThermalFlo HP heat pump. It will control incoming water temperature between a minimum of 60º and a maximum of 104º F. The controller also serves as system status indicator, using LED lights and error codes, see Figure 15.
During normal operation, the controller displays the temperature of the water returning to the heat pump. Changing the desired pool or spa temperature is easily done by simply pressing the appropriate “Up” or “Down” arrow until the display reads the desired temperature. The display returns to current water temperature when setpoint adjustment is complete.
Todisplaythecurrentsetpoint,simplytouchtheappropriate“Up”or“Down”arrow. Thedisplaywillmomentarily display the current setpoint. Note that the POOL LED must be on to display or adjust the pool setpoint and the SPA LED must be on to display or adjust the spa setpoint.
WATER PRESSURE
THERMOSTAT
HEATING
COOLING
ERROR CODES:
E01 | - Low Refrigerant Pressure |
E02 | - High Refrigerant Pressure |
E03 | - Remote Error |
E04 | - Switch Fault |
Err | - Thermistor Error |
LO | - Water Temperature Low |
HI | - Water Temperature High |
TEMPERATURE SETTING
AUTO- HEAT/COOL | POOL | SPA |
PRESS ANY ARROW ONCE TO
CHECK SET TEMPERATURE
Figure 15. Main Control Panel