12

Wiring Diagram

460812, 460813, 460814, 460815, 460822, 460804

10K

 

 

Thermistor

Heat Pump Control Board

REMOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

SPA

COM

POOL

 

 

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

Switch factory set to H

 

 

 

 

THERMISTER

 

 

 

 

 

 

 

 

 

 

 

for 460812, 460813,

 

 

Optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reversing Valve on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460814, 460815, set to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460822

 

 

 

 

FLO

W

 

 

 

H

C AU

 

 

 

 

 

OLENOID

C for 460804, and set to

 

 

 

 

 

 

 

 

 

 

S

 

 

 

 

 

AU for 460822

 

 

 

 

 

 

ER

 

PRE

LOW

 

 

 

 

 

 

 

 

 

 

 

 

HI

 

24 VAC

FA

N

 

 

 

(on back of circuit board)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAT

 

 

 

 

PRES

 

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TBL

 

 

TBR

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

1

BLUE

 

 

WHITE

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

2

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PURPLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

3

WHITE

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PURPLE

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

4

WHITE

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

5

BLACK

 

 

 

5

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

6

BLACK

 

 

 

6

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

7

RED

 

 

 

 

 

 

Water Pres Sw

 

 

 

Hi Ref Pres Sw

Lo Ref Pres Sw

 

RED

8

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

COM

ORANGE

 

 

Capacitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VAC

24

 

 

 

 

50 mf

 

 

 

 

7.5 mf

 

 

 

 

 

 

 

 

 

208 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PURPLE

 

PINK

 

 

BROWN

 

 

 

 

 

 

 

 

 

 

240 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

TAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

COM

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BROWN

Relay

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

 

 

 

PURPLE

 

Contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BROWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BROWN

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

WHITE

 

 

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

 

 

 

 

 

 

 

Compressor

C

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

PURPLE

RED

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Incoming 220 VAC

Power Connection

Figure 11.

473073

ThermalFlo Installation and User’s Guide

Page 20
Image 20
Pentair ThermalFlo important safety instructions Wiring Diagram, 460812, 460813, 460814, 460815, 460822

ThermalFlo specifications

Pentair ThermalFlo is a leading-edge solution designed to address the evolving demands of thermal management in various industrial applications. As organizations prioritize energy efficiency and temperature regulation, ThermalFlo emerges as a robust offering from Pentair, a global leader in water and fluid management.

One of the standout features of Pentair ThermalFlo is its innovative heat tracing technology. This system employs electrical heat tracing cables that are strategically engineered to maintain desired temperatures in pipes, valves, and other critical components. The design minimizes the risks of freezing, ensuring that fluids can flow seamlessly, even in harsh environments. Moreover, it enhances safety by reducing the likelihood of pipe bursts due to thermal stress.

ThermalFlo also incorporates advanced insulation technologies that complement its heat tracing capabilities. The combination of these two approaches ensures optimal energy efficiency, reducing heat loss and lowering operational costs. When used in conjunction with smart monitoring systems, organizations can achieve real-time temperature control, allowing for proactive adjustments that enhance system efficiency.

Another significant characteristic of Pentair ThermalFlo is its versatility. This solution can be customized to suit various applications, from oil and gas industries to food processing and pharmaceuticals. The adaptability of ThermalFlo makes it an ideal choice for facilities looking to improve their thermal strategies without compromising on performance.

In addition to its technical features, Pentair ThermalFlo emphasizes sustainability. By promoting energy efficiency and reducing heat loss, the system contributes to lower carbon footprints for its users. This aligns with the growing trend of adopting environmentally responsible practices within industry, showcasing Pentair’s commitment to innovative solutions that meet modern challenges.

Furthermore, the installation and maintenance of ThermalFlo systems are streamlined, with user-friendly features that simplify the process for engineers and technicians. Its robust design ensures long-lasting performance, reducing downtime and maintenance costs over time.

In conclusion, Pentair ThermalFlo stands out in the marketplace through its blend of innovative technologies, energy efficiency, and adaptability across different industries. As businesses increasingly seek effective thermal management solutions, ThermalFlo represents an investment in reliability, safety, and sustainability.