CHLORINATOR PLACEMENT

1.All chlorinators should have a chemical resistant check valve and a loop plumbed at least 8 inches above the chlorinator, between it and the heater, as far down line from the heater as possible.

2.Never plumb a chlorinator into the suction side of the circulation pump. All automatic chemical feeders should be as far down line of the heaters water flow as possible.

3.Off line type chlorinators should be tapped into the plumbing only as shown on the diagram. See pool/spa combinations requiring special placement. See plumb- ing diagram.

4.Never install a chlorinator at a higher elevation than the lowest heater piping even if a loop check valve is used. Doing so may allow chlorine to migrate to the heat exchanger, causing damage.

5. Do not allow floating chlorinators to be drawn up to the skimmer inlet.

6.Keep the chlorinator lid o-ring lubricated with sili- cone grease. Replace when needed.

No chemicals or chlorine tablets in the skimmer !!!

Off Line Type

Chlorinator

ADDING CHEMICALS

CAUTION

Absolutely no chemicals in the skimmer !

Do not place any chemicals in the skimmer throat. Chlorine tablets placed in the skimmer will allow a concentrated solution of chlorine to pass through the heat exchanger causing damage.

7.Do not place any chemicals in the pump lint trap cav- ity or filter. Make sure the lint trap basket is placed properly to prevent debris from clogging the heat ex- changer.

8.Do not over load chlorinator feeder cavity. Exces- sive amounts of chlorine tablets will increase the chance of migration of acetic, concentrated chlorine to migrate to the heat exchanger causing damage. 25% of maxi- mum is suggested.

9.When adding gas chlorine make sure that the pH does not drop below 7.4. Make sure that the total alkalinity does not drop below 90 p.p.m. Gas chlorine is very ace- tic.

10.Do not isolate the heater from the water flow unless you have installed a drain plug to drain all the water from the heat exchanger and then blow out with pres- surized air. Stagnant water will corrode the heat ex- changer and piping.

Chemical Loop

8" Above

Chlorinator

2lb Chemical Resistant

Check Valve

In Line Type

Chlorinator

See plumbing & water flow and high rate water pumps for more information.

Page 23
Image 23
Pentair XLS600, XLS800, XLS1000 Chlorinator Placement, Adding Chemicals, No chemicals or chlorine tablets in the skimmer

XLS1000, XLS800, XLS600, HP 400, HP 600, HP 800, HP 1000, HP 230, CP12 specifications

Pentair is a recognized leader in providing innovative filtration and pumping solutions, and among its noteworthy offerings are the CP12, HP 400, HP 600, HP 800, HP 1000, HP 230, XLS600, XLS800, and XLS1000 models. Each of these products is designed with unique features and advanced technologies that meet diverse customer needs across various applications.

The Pentair CP12 is a compact and efficient pump designed for residential water management. Known for its ease of installation and reliable performance, the CP12 incorporates a high-efficiency motor that minimizes energy consumption while ensuring effective water circulation.

Moving to the HP series, the HP 400, 600, 800, and 1000 models boast powerful performance characteristics suited for heavy-duty applications. These pumps are engineered with robust materials for longevity and durability. With advanced hydraulic designs, they deliver excellent flow rates and pressure, making them ideal for applications like irrigation, water feature management, and even light industrial use. The HP series also features smart technology that allows for remote monitoring and control, enhancing operational efficiency.

In the mid-range, the HP 230 model offers versatility with its multi-purpose capabilities. Designed for residential and light commercial use, it strikes a perfect balance between performance and energy efficiency, ensuring optimal operation without excessive energy costs.

The XLS series, which includes the XLS600, XLS800, and XLS1000 models, targets larger commercial applications. These models are equipped with cutting-edge technology designed for superior flow and pressure management, making them perfect for high-capacity requirements. Their variable speed operation allows for customizable performance tailored to specific system needs, while advanced monitoring capabilities enhance reliability and maintenance scheduling.

All of these Pentair pumps prioritize environmental responsibility with energy-efficient designs that reduce carbon footprints. Key features across the range include corrosion-resistant materials, thermal protection for added safety, and user-friendly interfaces that simplify operation and monitoring.

In conclusion, Pentair’s CP12, HP series, and XLS series pumps stand out due to their innovative technologies, impressive performance capabilities, and commitment to energy efficiency. Whether for residential or commercial applications, these models cater to a wide range of needs, ensuring customers can find effective solutions for their water management challenges.