OPERATIONAL SEQUENCE

THERMOSTAT CONTROL & SETTINGS

 

EVAPORATOR AIR COIL

 

 

 

 

Turning up the thermostat will start the

The fan circulates the warmer out-

 

 

 

unit running. When the pool water has

side air through the evaporator air

 

 

 

coil to collect any available heat. The

 

 

 

been heated to the thermostat setting, the

 

 

 

cooler Freon™ absorbs this heat

 

 

 

unit will shut off. When the pool water

 

 

 

causing it to evaporate into a gas.

 

 

 

temperature loses one to two degrees,

 

 

 

Therefore the compressor can com-

 

 

 

the thermostat will activate the unit.

 

 

 

press the gas to maximize the gain

 

 

 

There are no temperature graduate num-

 

 

 

heat from the air. The fan discharges

 

 

 

bers printed on the thermostat face.

To

cooler air when the compressor is running. Process is

obtain an exact temperature, turn the t-stat

 

reversed in Heat & Cool models while in cooling mode.

all the way up and then place a pool type

 

COMPRESSOR

 

 

 

thermometer in the pool water itself. Once

 

Once the fan is running, the compressor will start 5 to

the water has reached your target tempera-

 

7 minutes later, it's controlled by a time delay device.

ture on the thermometer, turn the thermo-

 

The compressor pumps and compresses re-

 

stat knob backwards until the heater just

 

frigerant gas. When refrigerant gas is com-

 

shuts off. Make a mental note of knob in-

 

pressed it intensifies the heat before it is

 

dicator. Therefore your thermostat will be

 

release to the pool water. This compressed

 

set at the thermometer reading.

 

hot gas is pumped through the heat ex-

 

THERMOSTAT CONTROL & SETTINGS FOR

changer where it delivers heat to the pool

 

water passing through the same heat ex-

 

HEAT & COOL MODELS

 

 

 

changer.

 

 

 

 

 

For heating modes on these models,

 

 

 

 

 

make sure toggle is selected to heat and

HEAT EXCHANGER

 

 

 

 

follow the previous instructions above.

The compressed hot refrigerant releases it's heat to the

 

For cooling mode make sure toggle is

pool water inside the heat exchanger. The exchanger is

 

selected to cool. Turning down the ther-

a tube within a tube construction, water passing through

 

mostat counter clockwise will start the

 

the inner tube, hot gas passing

Heat Cool

unit running. When the pool water has

 

through the outer tube. The refriger-

been cooled to the thermostat setting,

 

ant is transformed into a liquid state

 

 

 

the unit will shut off. When the pool

 

as it exits the heat exchanger. There-

water temperature rises one to two degrees, the thermo-

 

fore it is also referred to

 

stat will activate the unit. There are no temperature gradu-

as a condenser coil. (Heat & Cool Models,

 

ate numbers printed on the thermostat face. To obtain an

process is reverse). The exchanger is en-

 

exact temperature, turn the t-stat all the way down

and

cased inside a block of closed cell foam to

 

then place a pool type thermometer in the pool water it-

prevent heat loss and corrosion.

 

 

self. Once the water has reached your target temperature

 

See the cross section.

 

on the thermometer, turn the thermostat knob forwards SYSTEM OVERVIEW Warm Water Cool Water

until the heater just shuts off. Therefore your thermostat

The heat pump system

In

Out

will be set at the thermometer reading.

 

uses 410-A refrigerant to

 

 

 

FAN-AIR CIRCULATION

 

transfer the heat from the

 

 

 

 

outside air to the pool

 

 

 

Once the t-stat is activated the

 

 

 

 

 

water.

 

 

 

 

fan will begin to turn. To ab-

 

Cool Air Out

 

Plumbing Bypass

 

 

 

 

sorb heat energy, the fan circu-

 

 

 

 

 

Manifold

lates warmer air through the

 

 

 

 

 

 

evaporator coil at about 4000

 

 

 

 

Hot Gas

cubic feet per minute. The fan

 

Warm

 

 

 

 

runs independently from the

 

Air

 

 

 

 

compressor. The compressor

 

In

 

 

 

 

 

 

 

 

 

 

will start within 5 to 7 minutes

 

 

Freon™

 

Heat

Compressor

after the fan.

 

9

Air Coil

 

 

Lines

 

 

 

 

 

 

Page 9
Image 9
Pentair HP 400, HP 600, HP 800, HP 1000, HP 230 Thermostat Control & Settings Evaporator AIR Coil, Heat & Cool Models

XLS1000, XLS800, XLS600, HP 400, HP 600, HP 800, HP 1000, HP 230, CP12 specifications

Pentair is a recognized leader in providing innovative filtration and pumping solutions, and among its noteworthy offerings are the CP12, HP 400, HP 600, HP 800, HP 1000, HP 230, XLS600, XLS800, and XLS1000 models. Each of these products is designed with unique features and advanced technologies that meet diverse customer needs across various applications.

The Pentair CP12 is a compact and efficient pump designed for residential water management. Known for its ease of installation and reliable performance, the CP12 incorporates a high-efficiency motor that minimizes energy consumption while ensuring effective water circulation.

Moving to the HP series, the HP 400, 600, 800, and 1000 models boast powerful performance characteristics suited for heavy-duty applications. These pumps are engineered with robust materials for longevity and durability. With advanced hydraulic designs, they deliver excellent flow rates and pressure, making them ideal for applications like irrigation, water feature management, and even light industrial use. The HP series also features smart technology that allows for remote monitoring and control, enhancing operational efficiency.

In the mid-range, the HP 230 model offers versatility with its multi-purpose capabilities. Designed for residential and light commercial use, it strikes a perfect balance between performance and energy efficiency, ensuring optimal operation without excessive energy costs.

The XLS series, which includes the XLS600, XLS800, and XLS1000 models, targets larger commercial applications. These models are equipped with cutting-edge technology designed for superior flow and pressure management, making them perfect for high-capacity requirements. Their variable speed operation allows for customizable performance tailored to specific system needs, while advanced monitoring capabilities enhance reliability and maintenance scheduling.

All of these Pentair pumps prioritize environmental responsibility with energy-efficient designs that reduce carbon footprints. Key features across the range include corrosion-resistant materials, thermal protection for added safety, and user-friendly interfaces that simplify operation and monitoring.

In conclusion, Pentair’s CP12, HP series, and XLS series pumps stand out due to their innovative technologies, impressive performance capabilities, and commitment to energy efficiency. Whether for residential or commercial applications, these models cater to a wide range of needs, ensuring customers can find effective solutions for their water management challenges.