42
Line Commands
Set Line Interface
Description Configures line interface (hardware) parameters.
User Level Admin
Syntax set line .|<number>|* interface eia-232 [monitor-dcd on|off]
[monitor-dsr on|off] [flow none|soft|hard|both]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|9600|
19200|38400|57600|115200|230400|28800|custom <baud_rate>]
set line interface eia-422 [flow none|soft|hard|both]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|custom <baud_rate>]
set line .|<number>|* interface eia-485-half-duplex
[tx-driver-control auto|rts] [flow none|soft]
[echo-suppression on|off]]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|custom <baud_rate>]
set line interface eia-485 [tx-driver-control auto|rts]
[flow none|soft]
[duplex full|duplex half [echo-suppression on|off]]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|custom <baud_rate>]
Options eia-232 | eia422 | 485
Specifies the type of line that is being used with the IOLAN. Select either EIA-232,
EIA-422, or EIA-485 (TS2 supports only EIA-232).
monitor-dcd
Specifies whether the RS-232 signal DCD (Data Carrier Detect) should be monitored.
This is used with modems or any other device that sends a DCD signal. When it is
monitored and the IOLAN detects a DCD signal, the line service is started. Default is
Off. If both Monitor DCD and Monitor DSR are enabled, both signals must be detected
before the line service is started.
monitor-dsr
Specifies whether the RS-232 signal DSR (data set ready) should be monitored. This is
used with modems or any device that sends a DSR signal. When it is monitored and the
IOLAN detects a DSR signal, the line service is started. Default is Off. If both Monitor
DCD and Monitor DSR are enabled, both signals must be detected before the line
service is started.
flow
Defines whether the data flow is handled by the software (Soft), hardware (Hard),
Both, or None.
tx-driver-control
Used with a EIA-485 serial interface, if your application supports RTS (Request To
Send), select this option. Otherwise, select Auto. Default is Auto.
duplex
Specify whether the line is Full Duplex (communication both ways at the same time) or
Half Duplex (communication in one direction at a time).