Set IOChannel

trigger

When the trigger condition is met, triggers the specified alarm action. Triggers can be: z Disabled—No alarm settings. This is the default.

z Inactive—When the expected Digital input is active, going inactive will trigger an alarm.

z Active—When the expected Digital input is inactive, going active will trigger an alarm.

clear

Specify Manual to manually clear an alarm. Specify Auto to automatically clear the alarm when the trigger condition changes; for example, if the Trigger is Inactive and the alarm is triggered, once the input becomes active again, the alarm will be cleared when Auto is set. The default is Auto.

syslog

Sends a message to syslog when an alarm is triggered or cleared. The syslog entry includes the severity level and the value that caused the alarm to trigger or clear. The syslog message is associated with Level Critical.

 

snmp

 

Sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the

 

severity level and whether the alarm was triggered or cleared.

 

description

 

Provide a description of the channel, making it easier to identify. The channel

 

description can be up to 20 characters.

 

invert-signal

 

Inverts the actual condition of the I/O signal in the status; therefore, an inactive status

 

will be displayed as active.

 

latch

 

Latches (remembers) the activity transition (active-to-inactive or inactive-to-active).

 

The latched status is maintained until it is read. Once it is read, it will revert to the

 

current status. The default is disabled.

Set IOChannel Digital Input (Serial Pins)

Description

Sets the Digital input settings for serial pins CTS, DSR, and DCD. This option is only

User Level

available when the Line Service is set to Signal I/O.

Admin

Syntax

set iochannel ctsdsrdcd

 

[alarm [trigger disabledinactive-inputactive-input]

 

[clear automanual] [syslog onoff] [snmp onoff]]

 

[description <string>] [invert-signal onoff]

 

[latch disabledinactive-to-activeactive-to-inactive]

Options

digital_channel

Specify the Digital channel number, for example, d2. alarm

Configures alarm settings when the Digital input trigger is activated.

77

IOLAN DS1/TS2 CLI Reference Guide, Version 4.3

Page 76
Image 76
Perle Systems 5500208-43 manual Set IOChannel Digital Input Serial Pins

5500208-43 specifications

Perle Systems 5500208-43 is a highly advanced device in the realm of serial device connectivity and management. Designed to facilitate seamless communication between legacy serial devices and modern network infrastructure, this device serves as a reliable solution for numerous industrial and commercial applications.

One of the main features of the Perle 5500208-43 is its ability to connect up to 16 serial devices simultaneously over a single Ethernet connection. This multi-port capability is made possible through its robust architecture, allowing businesses to expand their network without the hassle of complex cabling. The device is equipped with 16 RS-232 serial ports, ensuring compatibility with a wide range of devices including printers, sensors, and legacy machines.

In terms of technologies, the 5500208-43 utilizes Perleā€™s advanced IOLAN technology which offers a host of features designed for efficiency and reliability. This technology not only ensures high-speed data transmission but also enables users to easily manage and configure the device through a user-friendly web interface. Furthermore, the device's support for various protocols, including TCP/IP, UDP, and SNMP, provides significant flexibility, allowing integration into existing IT infrastructures with ease.

Another notable characteristic of the Perle 5500208-43 is its rugged design. Built to withstand harsh environments, it is perfect for deployment in industrial settings where exposure to dust, humidity, and temperature variations can be a concern. The device supports industrial-grade power inputs, including PoE (Power over Ethernet), providing added convenience in installation and maintenance.

Security is also a top priority in the design of the 5500208-43. It incorporates features such as secure socket layer (SSL) encryption and user authentication to ensure that data remains protected during transmission. This makes it particularly suitable for applications requiring secure data handling, such as in healthcare, finance, and government sectors.

Additionally, the Perle 5500208-43 is backed by a solid warranty and technical support, giving customers peace of mind that they are investing in a reliable product. With its combination of versatility, durability, and advanced technology, this device stands out as a crucial component in bridging the gap between traditional serial devices and modern network systems.