2.Type set server internet <IPv4 address>netmask <mask>[Enter]

Example:

set server internet 196.12.10.9 netmask 255.255.255.0[Enter]

1.Type save [Enter]

2.When prompted “Save config to flash ROM y/n” [Enter]

3.Type reboot [Enter]

4.When prompted “Confirm reboot unit y/n [Enter]

5.When the Management module reboots, the IP address you entered will be active. You can now use your favourite web browser to configure the module. Simply enter the IP address in the web browsers address field and press [Enter].

6.You can also use Telnet, SSH or SNMP to configure the Management module.

Resetting the MCR-MGT Management Module To Factory Default Settings

If it becomes necessary to return the Management module to the factory default settings, press and hold the “RESET” button on the front of the module for 3 seconds (you can use a paper clip to do this). This will return the configuration to the factory default settings and will force the module to reboot.

PERLE SMI MEDIA CONVERTER GUIDE 14

Page 14
Image 14
Perle Systems 5500316-13 manual Resetting the MCR-MGT Management Module To Factory Default Settings