MCR-MGT “PWR” LED is RED

The MCR-MGT module is defective. It will need to be replaced.

MCR-MGT “PWR” LED is Blinking Green

The MCR-MGT module is in the process of booting up. If this state persists for longer then one minute, reset the module by momentarily pressing the reset switch on the front of the module. See Front view – reset switch .

Cannot connect serially to MCR-MGT Module

1.Make sure that the PWR LED is “Green”

2.Ensure that you are using the right cable/adapter.

3.If you see garbage characters, the baud rate of the serial port may have been changed from the original 9600 baud. Configure your terminal emulation to match configured speed.

4.If you don’t know what the speed is, you could reset the module to “factory default” by pressing and holding the reset switch (3 seconds) on the front of the MCR-MGT module. NOTE: this will erase the entire configuration back to a factory default state.

Cannot connect to MCR-MGT Module using an IP address

1.Make sure that the PWR LED is “Green”

2.Make sure that the LKC LED is “Green”. (Copper link connection is up).

3.Make sure you are using the IP address which is configured on the MCR-MGT module.