A470 Users GuidePertech® 2006 iv

Important Information to the User

In order to ensure compliance with the Product Safety, FCC, and CE marking requirements, you must use the power supply,
power cord, and interface cable, which were shipped with this product or which meet the following parameters:
Power Supply
Input power to this product must be provided by one of the following:
(1) A NRTL Certied power source with a Limited Power Source.
(LPS) output for use in North America, input rated 100-240 Vac, 1.5 A, 50/60 Hz, output rated 24 Vdc at 2.5 A. Maximum and
60W Maximum, or
(2) A Power source with a Limited Power Source (LPS) output Certied by an agency recognized in the country of installation,
input rated 100-240 Vac, 1.5 A, 50/60 Hz, output rated 24 Vdc at 2.5 A. Maximum and 60W Maximum.
Use of this product with a power supply other than the Pertech power supply will require you to test this power supply and
Pertech printer for FCC and CE mark certication.
Interface Cable
A shielded (360 degree) interface cable must be used with this product. The shield must be connected to the frame or earth
ground connection or earth ground reference at EACH end of the cable.
Use of a cable other than described here will require that you test this cable with the Pertech printer and your system for FCC
and CE mark certication.
Power Cord
For North America a NRTL recognized detachable power cord must be used. For applications where the power supply module
may be located on the oor, a power cord with Type SJT marking must be used.
For applications outside North America, power cords which meet the country of installation’s certication and application
requirements must be used.
Use of a power cord other than described here may result in a violation of safety certications which are in force in the country of
use.