Philips 241P3 user manual Mtbf

Models: 241P3

1 61
Download 61 pages 40.06 Kb
Page 29
Image 29

4.Technical Specification

Power (241P3LY)

On mode

26W (typ.), 36W(max) (with audio and USB x 1)

On mode (ECO mode) (typical)

14W

 

 

Energy Consumption

AC Input Voltage at

AC Input Voltage at

AC Input Voltage at

(EnergyStar 5.0 test method)

100VAC +/-5VAC,

115VAC +/-5VAC,

230VAC +/-5VAC,

 

50Hz +/- 3Hz

60Hz +/- 3Hz

50Hz +/ -3Hz

Normal Operation (typical)

19.32W

19.16W

18.9W

Sleep (typical)

0.5W

0.5W

0.5W

Off

0.3W

0.3W

0.3W

Heat Dissipation*

AC Input Voltage at

AC Input Voltage at

AC Input Voltage at

 

100VAC +/-5VAC,

115VAC +/-5VAC,

230VAC +/-5VAC,

 

50Hz +/ -3Hz

60Hz +/ -3Hz

50Hz +/ -3Hz

Normal Operation

65.94BTU

65.38BTU

61.51BTU

Sleep (typical)

1.71BTU

1.71BTU

1.71BTU

Off

1.024BTU

1.024BTU

1.024BTU

 

 

Power LED indicator

On mode: White, Standby/Sleep mode:White (blinking)

Power Supply

Build-in, 100-240VAC, 50/60Hz

 

Dimension

 

 

 

Product with stand (WxHxD)

570 x 507 x 220mm

 

 

Product without stand

570 x 353 x 62mm

 

 

(WxHxD)

 

 

 

Box dimension (WxHxD)

670 x 268 x 413mm

 

 

Weight

 

 

 

Product with stand

6.6kg (241P3/241P3Y), 6.0kg (241P3L/241P3LY)

Product without stand

4.4kg (241P3/241P3Y), 3.8kg (241P3L/241P3LY)

Product with packaging

9.3kg (241P3/241P3Y), 8.7kg (241P3L/241P3LY)

Operating Condition

 

 

 

Temperature range

Storage: -20°C to 60°C

 

 

operation: 0°C to 40 °C

 

Relative humidity

20% to 80%

 

 

Altitude

Non-operation: + 40,000 ft ( 12,192 m)

 

 

 

 

 

operation: + 12,000 ft ( 3,658 m)

 

 

 

MTBF

50,000 hrs (241P3/241P3Y), 30,000 hrs (241P3L/241P3LY)

 

 

 

 

27

Page 29
Image 29
Philips 241P3 user manual Mtbf