Philips 245P2 Troubleshooting & FAQs, The Auto Function is not applicable in, Common Problems

Models: 245P2

1 59
Download 59 pages 10.29 Kb
Page 52
Image 52
Troubleshooting & FAQs

7.

Troubleshooting & FAQs

AUTO button doesn't function

• The auto function is applicable only in

 

 

 

 

 

VGA-Analog mode. If the result is not

7.1

Troubleshooting

 

satisfactory, you can do manual adjustments

This page deals with problems that can be

 

via the OSD menu.

 

 

corrected by a user. If the problem still persists

 

Note

after you have tried these solutions, contact Philips

 

The Auto Function is not applicable in

customer service representative.

 

DVI-Digital mode as it is not necessary.

 

 

Common Problems

Visible signs of smoke or sparks

 

 

No Picture (Power LED not lit)

• Do not perform any troubleshooting steps

• Disconnect the monitor from mains power

Make sure the power cord is plugged into the

 

source immediately for safety

 

 

power outlet and into the back of the monitor.

• Contact with Philips customer service

First, ensure that the power button on the

 

representative immediately.

 

 

front of the monitor is in the OFF position,

 

 

 

 

then press it to the ON position.

 

Imaging Problems

 

 

 

No Picture (Power LED is white blinking)

Image is not centered

Make sure the computer is turned on.

• Adjust the image position using the “Auto”

Make sure the signal cable is properly

 

function in OSD Main Controls.

 

 

connected to your computer.

• Adjust the image position using the Phase/

make sure the monitor cable has no bent pins

 

Clock of Setup in OSD Main Controls. It is

 

 

on the connect side. If yes, repair or replace

 

valid only in VGA mode.

 

 

the cable.

 

 

The Energy Saving feature may be activated

Image vibrates on the screen

Screen says

• Check that the signal cable is properly securely

 

connected to the graphics board or PC.

 

 

 

 

Vertical flicker appears

Make sure the monitor cable is properly

 

 

 

 

connected to your computer. (Also refer to

 

 

 

 

the Quick Set-Up Guide).

• Adjust the image using the “Auto” function in

Check to see if the monitor cable has bent

 

OSD Main Controls.

 

 

pins.

• Eliminate the vertical bars using the Phase/

Make sure the computer is turned on.

 

Clock of Setup in OSD Main Controls. It is

 

 

 

 

 

valid only in VGA mode.

50