12 English
Problem | Solution |
| Clean the filters and the corona particle charger (see chapter ‘Cleaning |
| and maintenance’). If this does not help, unplug the appliance and take it |
| to your Philips dealer or an authorised Philips service centre. |
The odours are not | The zeolite gas filter may be dirty or may have reached the end of its |
removed properly. | life. Clean the zeolite gas filter (see chapter ‘Cleaning and maintenance’) |
| or replace it (see chapter ‘Filter replacement’). |
| Perhaps you use the appliance in a room in which the ambient air |
| quality is very poor. In that case, open windows to improve the air |
| circulation. |
| Perhaps you use the appliance in a room that is much bigger than the |
| room size the appliance is intended for. Put the appliance in a smaller |
| room.The recommended room size is 6m² up to 20m² for AC4054/ |
| AC4052 and 6m² up to 40m² for AC4064/AC4062. |
The dust particles are | The ESP particle filter may have reached the end of its life. Check the |
not removed properly. | colour of the ESP particle filter (see chapter ‘Filter Replacement’). If |
| necessary, replace the filter. |
| Perhaps you use the appliance in a room that is much bigger than the |
| room size the appliance is intended for. Put the appliance in a smaller |
| room.The recommended room size is 6m² up to 20m² for AC4054/ |
| AC4052 and 6m² up to 40m² for AC4064/AC4062. |
The fans do not work, | The appliance may be malfunctioning. Switch off the appliance and |
even though the | unplug it.Take the appliance to your Philips dealer or an authorised |
appliance is plugged in | Philips service centre. |
and switched on. |
|
The appliance produces | The |
an unusual noise (e.g. a | ‘Cleaning and maintenance’). |
hissing, sizzling or |
|
crackling noise) during |
|
operation. |
|
| Perhaps you forgot to remove the plastic wrapper of a new filter. |
| Remove the plastic wrapper before you switch on the appliance again. |
| The air inlet or outlet may be blocked by external objects. Remove the |
| object that blocks the air inlet or outlet. |
| The appliance may be malfunctioning. Switch off the appliance and |
| unplug it.Take the appliance to your Philips dealer or an authorised |
| Philips service centre. |
| Perhaps the mesh of the corona particle charger is not clean. Clean the |
| corona particle charger (see chapter ‘Cleaning and maintenance’). |
The appliance produces | The appliance may be malfunctioning. Switch off the appliance and |
a burning smell during | unplug it.Take the appliance to your Philips dealer or an authorised |
operation | Philips service centre. |
The appliance gives off | In case of an unusual smell, contact an authorised Philips service centre. |
an unusual smell during |
|
operation. |
|