9. Maintenance

Lamp

When operation time reaches the last 100 hours

of the average lamplife, the

Multimedia projectors

message ‘Warning: lamplife

Warning:

has almost expired’ will be

Lamplife has almost expired

displayed on the screen,

It is suggested to have a spare lamp available.

each time the projector is

The lamp type is indicated in the user guide.

switched on. The lamp

 

indicator lights up orange.

 

 

 

The lamplife remaining can be checked using the OSD

menu.

Display

Picture

Audio

Settings

1.

Press the Menu.

Language

 

 

 

The menu bar appears

Keystone correction

 

 

 

on the screen.

Start-up screen

 

 

 

 

Lamp counter

 

 

 

2.

Use Cursor Control to

System information

 

 

 

move the cursor to

Factory reset

 

 

 

 

Settings.

(more)

 

 

 

 

 

 

 

 

3.

Use Cursor Control to

Lamp

 

Projector

 

 

select Lamp counter.

5 hours

 

2453 hours

 

 

 

 

 

 

The remaining lamplife Lamp counter shows the operating hours of the

hours are displayed in

lamp. It is suggested to reset when a new lamp is

the action window at the

inserted. To reset keep OK key pressed

for 3 seconds.

bottom of the screen.

 

– When the lamplife has

 

 

expired,the lamp

 

indicator lights up red

Multimedia projectors

and the message

Warning:

‘Warning: lamplife has

Lamplife has expired

expired’ is displayed on

It is suggested to change the lamp,

the screen.

to avoid sudden failure and to improve

 

overall picture quality.

 

 

Lamp Replacement

Caution!

For cooling purposes the lamp is open. When removing the lamp do not tilt. If the inner tube is broken glass particles may fall out.

Be very careful. The lamp and lampholder may still be too hot to touch.

Keep lamp holder opening to your right. Do not touch lamp or point lamp holder opening at anyone.

A high-pressure lamp may break if handled improperly.

1.Press the Stand by button to switch off the projector.

– The standby indicator lights up red.

2.Wait 5 minutes for the lamp to cool down and the cooling fan to stop and disconnect the mains lead and all other cables.

3.Turn the projector over. Never place the projector on the side where the connections are located!

4.Unscrew the screws at the bottom of the cover and remove the cover.

5.Read the caution and warning labels on the lamp cover.

6.Unscrew the lamp holder.