!CAUTION

Please use earth line.

Do not place the earth line near water or gas pipes, lightning-conductor, or the earth

line of telephone. Improper installation of earth line may cause electric shock.

A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.

IMPORTANT

The wires in this mains lead are coloured in accordance with the following code:

Green-and-yellow

:

Earth

Blue

:

Neutral

Brown

:

Live

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green-and-yellow.

The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.

NOTE

If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized service/ parts centers.

ENGLISH

!CAUTION

Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply.

REGULAR INSPECTION

PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONAL EITHER EVERY HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP.

1

2

3

Is the earth line disconnected or broken?

Is the mounting frame seriously affected by rust and is the outdoor unit tilted or unstable?

Is the plug of power line firmly plugged into the socket? (Please ensure no loose contact between them).

Confirm

– 19 –

Page 19
Image 19
Philips RAC-18C9, RAS-18C9 instruction manual Regular Inspection