Installation & User’s Manual |
|
| PLCYC LED Luminaires | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| General |
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | Power Limit | 30W, 40W, 50W, 70W, | 100W | Sets the maximum power setting of the |
|
| 90W, 100W, 100W | LED engine. | |||
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| Off, Scratch Pad, |
| When the Fixture |
|
|
|
|
| output. Scratch Pad is an automatically | |
|
|
|
| Warm White, Cool |
| |
|
| 1 |
| saved Preset. Last Set is the last thing | ||
|
| White, Day Light, | Cool White | |||
|
| coming out of the fixture, this could be | ||||
|
|
|
| Preset30, Preset31, |
| |
|
|
|
|
| Warm White with the intensity changed | |
|
|
|
| Last Set |
| |
|
|
|
|
| from that of the Preset. | |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 3 | Reset Hours | No, Yes | No | Resets luminaire’s operational hours. |
|
|
|
|
|
|
|
|
| Presets |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Determines if the factory Calibrated |
|
| 3 | Protected | No, 5 - 25 | Yes | Presets' Colour Mix is protected from |
|
|
|
|
|
| changes. |
|
|
|
|
|
|
|
|
| 3 | Load Factory | No, Yes | No | Reload Factory Calibrated Presets, |
|
| Intensity changes will also be reloaded. | ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| DMX |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Enables or disabled DMX communication |
|
|
|
| No, Yes, or Wireless (if |
| through the luminaires DMX512 ports. |
|
| 3 | DMX Enabled | Yes | Sets the DMX feature to Wireless DMX (if | |
|
| equipped) | ||||
|
|
|
|
| wireless DMX option is installed - sold | |
|
|
|
|
|
| |
|
|
|
|
|
| separately). |
|
|
|
|
|
|
|
|
| 1 | Address | 001 to 512 | 001 | DMX512 address. Note, it can be set if |
|
| displayed. | ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Defines size/precision of DMX map. |
|
| 2 | Map | Colour Mixing/Intensity in | ||
|
| higher resolution for precision control. 3- | ||||
|
|
|
|
|
| |
|
|
|
|
|
| Chan provides minimal channel usage. |
|
|
|
|
|
|
|
|
|
|
| Off, Hold, Hold 8hr (8 |
| If DMX is detected and then goes away, |
|
| 2 | When no DMX | Hold | this defines what will happen to the output. | |
|
| hours), or | At end of 8Hr hold Fixture goes to Power- | |||
|
|
|
|
| ||
|
|
|
|
|
| Up setting. |
|
|
|
|
|
|
|
|
| Fan |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Normal - Normal Mode Provides higher |
|
|
|
|
|
| cooling margin for thermally challenging |
|
|
|
|
|
| applications. Recommended for full power |
|
| 3 | Normal / Quiet | Normal or Quiet | Quiet | (RGBW @ 100%) applications with large |
|
| and numerous changes in power. Quiet - | ||||
|
|
|
|
|
| |
|
|
|
|
|
| (Quiet Mode) Quite Mode is similar to |
|
|
|
|
|
| Normal mode, but it controls fan tightly to |
|
|
|
|
|
| reduce fan noise. |
|
|
|
|
|
|
|
|
| 3 | Max% | 0 to 100% | 100 | Sets the maximum fan speed |
|
|
|
|
|
|
|
|
| 3 | Min% | 0 to 100% | 1 | Sets the minimum fan speed |
|
|
|
|
|
|
|
|
| Display |
|
|
|
|
|
|
|
|
|
|
|
|
| 3 | Flip Display | No, Yes | No | Flips (inverts) Display and Keypad Arrows. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: To Exit the Settings screen, use the [ESC] key. [ESC] and [OK] can be used to cancel or save changes to an individual parameter. However, once a parameter has been accepted, by pressing [OK] that change cannot be undone/ canceled by pressing the [ESC] key.