Security Levels

Installation & User’s Manual

PLCYC LED Luminaires

 

 

Step 3. Select a Level to change ( Level 1 PIN / Level 2 PIN / Level 3 PIN).

Step 4. Press [OK] to edit using the [UP ARROW], [DOWN ARROW], [LEFT ARROW] or [RIGHT ARROW] keys to enter a four-digit password (using 0 to 9).

Step 5. Press [OK] to save changes. If you hit [ESC] (Escape) password will not be stored and process must be repeated.

Step 6. Password is set.

Note: The current security level is displayed next to the Security heading. Only Passwords at, or below, that level will be displayed for modification. The level can be changed by entering a higher level Password on the "Enter PassPIN line directly below the Security heading, like Step 4 above.

Security Levels

Security Level

Description

Default PassPIN

 

 

 

0

System is locked; the only key that is active is the Menu/ESC Key. When this key is pressed a

Not Applicable

PassPIN is requested.

 

 

 

 

 

1

All keys are Active.

1111

You can select any Preset, and change Intensity, set DMX Address.

 

 

 

 

 

2

Editing and Saving of Presets is added to Level 1 functionality.

2222

 

 

 

3

Operationally the same as level 2, however all settings are available on the Settings screen.

3333

 

 

 

Locking Fixture

To lock the fixture:

Step 1. At a Status Screen, press [MENU] and scroll to "Lock Fixture".

Step 2. Press [OK].

Step 3. Use [LEFT ARROW] or [RIGHT ARROW] keys to highlight "YES" ", press [OK].

Step 4. Fixture is now locked.

Note: When the Fixture is Locked only the [ESC]/[MENU] key is functional. Pressing this key will display a request for a password. When a valid password is entered the fixture is unlocked to the security level of the entered password.

4. Presets

Presets are Colour Mixes that are stored in the Fixture, they can be recalled to reproduce a specific output from the fixture. Presets are made up of a Colour Mix; Red, Green, Blue, and White. They also have Intensity associated with them.

Presets can be recalled via the User interface or by a DMX channel, when under DMX control. The Preset’s Intensity is applied if the User Interface is used; if DMX, the DMX Intensity channel is used for Intensity.

Presets Types

Presets are classified as Locked, Protected, or User. The type of preset determines what aspects of the Preset can be modified.

Locked

Locked Presets are factory Calibrated, and their Colour Mix cannot be changed by the user. Their Intensity can be changed. Three Presets (2-4), "Warm White', "Cool White", and "Day Light", are Locked.

Preset 0, the "off" preset is also Locked to the OFF value.