1999 May 10 17
Philips Semiconductors Preliminary specification
Universal Serial Bus (USB) CODEC UDA1325
Volume control
The volume of the UDA1325 can be controlled from 0 dB down to 60 dB (in steps of 1 dB). Below 60 dB the audio
signal is muted (−∞ dB). The setting of 0 dB is always referenced to the maximum available volume setting. Independant
volume control of the left and right channel is possible (balance control).
Table 9 Volume settings right playback channel
Table 10 Volume settings left playback channel
VR5 VR4 VR3 VR2 VR1 VR0 VOLUME (dB)
0000000
0000010
0000101
0000112
0001003
... ... ... ... ... ... ...
11110059
11110160
111110−∞
111111−∞
VL5 VL4 VL3 VL2 VL1 VL0 VOLUME (dB)
0000000
0000010
0000101
0000112
0001003
... ... ... ... ... ... ...
11110059
11110160
111110−∞
111111−∞