28. Too much chimney draft.
Remedy: Check draw with a draft gauge. Maximum draft .08 inches. If draw exceeds .08 reduce chimney outlet to accomplish.
29. Too little draft.
Remedy: Check draw of chimney with a draft gauge. Minimum draft .04 inches. May have to add more chimney.
30. Improper thermostat location.
Remedy: Relocate thermostat to location that reflects better overall desired temperature scheme.
31. Thermostat set too high.
Remedy: Turn it down to a more comfortable setting.
32.The heat demand of the house is too great for the BTU output of the furnace. Remedy:
33.Unit is oversized for the area to be heated.
Remedy: Replace with a smaller unit, or provide more air distribution to other rooms.
34.Not enough pellets placed in firepot on
Remedy: Stop operation, let the unit cool (never place pellets by hand into a hot firepot), and
35.Door or glass seal worn or broken.
Remedy: Replace with new gasket.
36. Draft inducer motor defective.
Remedy: Remove inducer motor from housing and connect to direct power, if non- functioning, replace with new motor.
37. Flue vent outlet blocked.
Remedy: Check piping and outlet to verify clear passage.
38.Summer (white) fan button pushed in on fan limit control. Remedy: Pull button back out to auto position.
39.Air shutter on draft inducer too far open.
Remedy: Close down air shutter to 50%.
40.Air shutter on draft inducer too far closed. Remedy: Open air shutter up to 50%.
41.Dust present due to carelessness when loading the stove. Remedy: Take your time when loading pellets into hopper.
42.Unit has run out of fuel.
Remedy: Load hopper.
24