19.Doors and heat exchanger surfaces of the furnace are hot during operation. DO NOT touch with bare hands, or allow children to play near the furnace unattended.
20.Do not allow anyone to operate the furnace that is not familiar with its operation.
21.Manually place fuel in the fire pot ONLY when starting a fire in a cold furnace. Never add pellets by hand to a smouldering fire or a hot fire pot. DANGEROUS smoking could result.
22.After lighting, make sure the main fire door and ash door are closed and sealed tight.
23.Set combustion air damper at not less than 50%. Damper settings will vary widely depending on draft characteristics of your chimney system. The unit should emit no visible smoke from the exhaust, if it does, open the damper slide until smoke is gone. Draft characteristics should be between .04 and .08 inches water.
5