I8 Water Cooker Computer Service

Pitco P/N PP11375

3.1Fahrenheit or Celcius Temperature Display:

This control will display temperatures in Fahrenheit(ºF).or Celsius(ºC) degrees. The default setting is degrees Fahrenheit(ºF).

With the control display showing [SELECT ], press product key 1. The display will show [DEGREE n] where n is the current setting, either F or C. Press the 0 key to scroll between the two options. Press the program key to save the setting. The control display will show [PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or press the program key to return to normal operations(display shows either [READY], [ACT xxx’F], or [FILLING ]).

1

3.2Password Settings:

The factory default setting for this control is password disabled. The default factory password for Level 1 and Level 2 programming is 6684. This default password will always work, regardless of the new password that can be entered using this option.

With the control display showing [SELECT ], press product key 2. The display will show

2

[SET PASS]. Press product key 0 to scroll between the two options [PASS REQ], and

 

 

[NO PASS ]. Press the program key to save this setting. If the [NO PASS ] option was

 

selected, the control display will show [PROGRAM ]. ]. Press product key 0 to select

 

 

more options below(display shows [SELECT ]) or press the program key to return to normal

 

operations(display shows either [READY], [ACT xxx’F], or [FILLING ]). If the [PASS REQ]

 

option was selected, the display will show [PASSxxxx], where xxxx is the current password.

 

Enter the new password using the product keys 0-9. Press the program key. The control display will show [PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or press the program key to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

3.3Beeper Volume Setting:

The volume setting of the beeper(alarm) can be set to low(1), medium(2) and high(3). The default value for the beeper volume is 3.

With the control display showing [SELECT ], press product key 3. The display will show

3

[VOLUME x] where x is the current volume setting. Press product key 0 to scroll through

the volume options. The control will beep using the volume setting currently shown on the display. Press the program key to save this setting. The control display will show [PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or press the program key to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

3.4

Language Selection:

 

 

 

This control can display text in English, Spanish, French, German and Dutch.

 

 

With the control display showing [SELECT ], press product key 4. The display will show

 

 

 

 

4

 

 

 

the current language setting of either [ENGLISH], [ESPANOL], [FRANCAIS],

 

 

 

[DEUTSCH], or [HOLLANDS]. Press product key 0 to scroll through the language

 

 

 

options. Press the program key to save this setting. The control display will show

 

 

 

 

 

 

[PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or

 

 

press the program key to return to normal operation(display shows either [READY], [ACT

 

 

xxx’F], or [FILLING ]).

 

 

L22-303 Rev 0 (01/07)

7

Page 7
Image 7
Pitco Frialator L22-303 service manual Fahrenheit or Celcius Temperature Display, Password Settings, Beeper Volume Setting