4.6Recovery Test Value:

I8 Water Cooker Computer Service

Pitco P/N PP11375

4.6Recovery Test Value:

This control records the heat up time for the appliance. A poorly running appliance will have an increased recovery time. Select this menu option to view the last recorded recovery time for this appliance. The recovery time is the length of time(in seconds) the appliance needs to heat the vat from 230°F to 280°F. This menu option is for display only.

With the control display showing [SERVICE ], press product key 7. The control display will

7

 

show [Rxxx-yyy], where xxx is the last recorded recovery time for this appliance, and yyy

 

 

is the factory default recovery time. Press the program key to exit it out of this menu

 

option. The display will now show [SERVICE ]. Continue on to the remaining service menu

 

options below, or press the program key twice to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

4.7More Service Menu Options:

With the control display showing [SERVICE ], press product key 8. The display will show [MORE ] for the More Service Menu.

The key indicators that light up will have options that can be adjusted. Any key indicators that do not light up do not have options that can be adjusted.

8

All of the Level 3 More Service Menu programming options shown below must begin with the control displaying this prompt [MORE ].

4.7.1Low Ready Level Adjustment:

This setting allows the READY idle message to be displayed a number of degrees below the current set temperature. For example, if the current set temperature is 180°F, and the READY idle display message is to be displayed from 175°F to 180°F, then this setting should be given a value of 5. The maximum value for this setting is 9 degrees.

With the control display showing [MORE ], press product key 1. The display will now show [RDY LO x], where x is the current Low Ready Level setting. Enter the new value using product keys 0-9. Press the program key to save this setting. The display will now show [MORE ]. Continue on to the remaining more service menu options below, or press the program key three times to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

1

4.7.2High Ready Level Adjustment:

This setting allows the READY idle message to be displayed a number of degrees above the current set temperature. For example, if the current set temperature is 180°F, and the READY idle display message is to be displayed from 180°F to 185°F, then this setting should be given a value of 5. The maximum value for this setting is 9 degrees.

With the control display showing [MORE ], press product key 2. The display will now show [RDY HI x], where x is the current High Ready Level setting. Enter the new value using product keys 0-9. Press the program key to save this setting. The display will now show [MORE ]. Continue on to the remaining more service menu options below, or press the program key three times to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).