10
Connect Power,
Turn It On/Off
Connecting Power, Turning It On/Off
Each display may draw up to 2.0A at 115V or 1.0A at 230V. For
countries outside of North America, it is the responsibility of the
installer to provide the power supply cord certified for use in the
destination country.
The power switch and power
receptacle are located at the left
rear of the display.
Connect a power cable to the
power supply. The power supply
is auto-ranging, so it works with
any source from 100 to 240 VAC,
50 to 60 Hz.

About UPS Supplies

Some installations use a UPS -
Uninterruptible Power Supply.
Most UPS devices will work with
the c50R/c67R. Review the
power specifications of your UPS
device to make sure it is compatible with the c50R/c67R.

Turning Power On/Off

1 With the power cord attached, turn on the power switch
located on the back of the unit.
2 Wait a few seconds and make sure that the green LED
Ready light is on.
3 Turn on the c50R/c67R by aiming the
remote at the screen and pressing the
ON button.
Note: It is normal to leave the power connected
and the power switch on all the time and turn the
lamps on and off as desired.
4 To turn off the c50R/c67R, press the OFF
button.
Note: You cannot turn off the lamps and then immediately turn them
on again. The lamps will not light until the mandatory cool-down
period of a minute has elapsed.