The following table defines the factory set values for the adjustable parameters.

Parameter

Default Setting

 

 

 

Power

On

 

 

 

Image Scale

Fill All

 

 

 

Contrast

150

( Range 0 -255)

 

 

 

Brightness

150

( Range 0 -255)

 

 

Color Temperature

7300C

 

 

Gamma

Linear

 

 

 

Backlight brightness*

255

 

 

 

 

*Backlight retains previous brightness settings.

Auto Power On

The display automatically turns on when power is restored after a power failure and maintains all operational settings. Note: “on/off” refers to the LCD panel and the backlight inverter.

Standby Mode

If no video is present, after 10 seconds, the display powers off (will power back on once video is detected.)

No Burn-in during Signal Loss

The AMLCD will not maintain any static self-generated images (such as a “no video” text box when video is not present), thus avoiding image burn in.

2.1.2Details of Command Implementation

All serial commands must be compatible with the Pixel works PW Host protocol defined in the Pixel works application note AN#77. Refer to AN #77 for protocol details.

The physical layer used for data exchange is RS232. No handshaking is used. Pin 3 of the DB-9 connector on the display is data transmitted from the host (Tx); pin 2 is data transmitted from the display and received by the host (Rx).