Planar LX1251TI Vesa Mount, Weight, Shipping Box, Service BOM, Humidity, Altitude, Vibration

Models: LX1251TI LX1250TI

1 35
Download 35 pages 37.31 Kb
Page 31
Image 31

VESA Mount

A VESA mount feature must be included on the LX1250TI, located on the back cover. Standard 100 and 75 mm VESA mount M4 x .7 threaded hole pattern. The holes shall be blind.

Additional M4 threaded mounting or cable management locations on rear of display also included to support vertical cable routing.

See Figure 2: Outline Drawing.

Weight

Weight <5.5lbs.

Shipping Box

Conforms to ISTA-2A (32 inch drop)

Maintenance Requirements/Service Support

Service Requirements

The LX1250TI requires no routine maintenance.

Service BOM

Service BOM provided on request.

Environmental Specifications

Temperature

 

 

Operating Temperature

 

-20° C to + 60° C (-4° to 140° F)

Storage Temperature

 

-20° C to + 85° C (-4° to 185° F)

Operating Survival Temp Range

-40° C to + 70° C

Humidity

 

 

Operating:

MIL-STD-810F (95% RH with 20° to 60° C temperature cycle for 11 days)

Altitude

 

 

Operating:

 

15K ft (IEC 60068 PT2-13, 4hr)

Non-operating:

 

30K ft (IEC 60068 PT2-13, 4 hr)

Vibration

 

 

Note: Tests performed with assemblies mounted in a rigid retaining fixture.

Operating ( Random):

10-500 Hz, 3.0G rms acceleration, 3 hours

per axis

 

Vibration, Endurance Sine Sweep

100-1100 Hz, 4 Gs rms, 1hr/axis

Shock

Note: Tests performed with monitor mounded in a rigid retaining assembly.

Operating/Non-operating: 50 g, 11 ms duration, ½ sine, 3 shocks per axis (IEC 60068 PT2-27)

LX1250TI User Manual