LLCF: Link Loss Carry Forward, “on” or “off”.
Enable: to enable the link of the Device, “on” or “off”.
Media 1LLR: Link Loss Return, “on” or “off”.
Auto: “A” for
Speed: to select the speed of the copper port, “10M”, “100M” or “1G”.
Dup: Duplex mode, “F” for Full Duplex or “H” for Half Duplex.
FC: Flow Control, “on” or “off”.
Enable: to enable the link of the Media 1, “on” or “off”.
Media 2
LLR: Link Loss Return, “on” or “off”.
Auto: “A” for
Dup: Duplex mode, “F” for Full Duplex or “H” for Half Duplex.
Enable: to enable the link of the Media 1, “on” or “off”.
Note: Some of the function can be control only depends on the Smart Media Converter
4.1.3.2.6 Redundant Backup SettingThe redundant function is to change the master line to the slave line in case of the linking fails happen.
The Redundant functions were set fixed, the master slot is slot 1 (odd number slot) and the slave slot is slot 2 (even number slot), and there are eight redundant groups in all. The “Act” will indicate what slot is active.
When the slave slot is active, and we need to transfer again to the master slot, push on the restart button.
13