PLANET Technology Corp.

GRT-101/401/402 User’s Manual

3.3.5 Advanced Setup

Advanced configuration contains SHDSL, WAN, Bridge, Route, NAT/DMZ and Virtual server parameters.

SHDSL

You can setup the Annex type, data rate and SNEXT margin for SHDSL parameters in SHDSL.

Click SHDSL

Annex Type: There are three Annex types, Annex A, Annex B and Annex AB in

SHDSL.

Link Type: For GRT-402 only, support two link type, 4-wire mode with 4.608 Mbps data rate and 2-wire mode with 2.304 Mbps data rate.

Data Rate: you can setup the SHDSL data rate in the multiple of 64kbps.

SHDSL SNEXT margin: the margin range is from –10 to 10.

The screen will prompt the parameters that will be written in machine. Be sure to confirm the modified parameters before rebooting and activating these changes in GRT series.

Press Restart button to restart GRT series working with new

parameters or press continue to setup another parameter.

WAN

GRT series supports up to 8 PVCs for WAN connections. You may specify

-22-