SpectraLink 8000 SVP Server: Administration Guide for SRP

Syslog Server

Logging can be set to Syslog or NONE. If Syslog is set, a message is sent
to the syslog server when an alarm is triggered.

Disable Telnet service

Prevents Telnet access into the SVP Server. Reset the SVP Server for
the change to take effect. Upon reset the Telnet protocol server is not
started.
The SVP Server must be reset in order to set the configuration options.
If the SVP Server is in Maintenance Lock, you must manually reset it by
selecting the Reset option in the SVP-II Configuration screen and then
pressing Y upon exit.
SVP Server Configuration
The SVP-II Configuration screen is where you set the mode of the SVP
Server. It is also where you can lock the SVP Server for maintenance
and reset the SVP Server after maintenance. The type of gateway you
are using determines the mode of the SVP Server. SVP-II Mode must be
set to NetLink for systems using the SpectraLink 8000 Telephony
Gateway.
From the main menu, scroll to SVP-II Configuration and select by
pressing Enter.
PN: 1725-36032-001_F.doc
24