Polycom Ceiling DocCam user manual Visca Command Setting Values, Exposure control, Ntsc PAL, Close

Models: Ceiling DocCam

1 22
Download 22 pages 40.09 Kb
Page 21
Image 21

38

Ceiling DocCam II — Appendix

Ceiling DocCam II — Appendix

 

39

 

VISCA Command Setting Values

Exposure control

 

 

NTSC

PAL

Shutter

15

10000

10000

Speed

14

6000

6000

 

 

 

 

 

 

13

4000

3500

 

 

 

 

 

12

3000

2500

 

 

 

 

 

11

2000

1750

 

 

 

 

 

10

1500

1250

 

 

 

 

 

0F

1000

1000

 

 

 

 

 

0E

725

600

 

 

 

 

 

0D

500

425

 

 

 

 

 

0C

350

300

 

 

 

 

 

0B

250

215

 

 

 

 

 

0A

180

150

 

 

 

 

 

09

125

120

 

 

 

 

 

08

100

100

 

 

 

 

 

07

90

75

 

 

 

 

 

06

60

50

 

 

 

 

 

05

30

25

 

 

 

 

 

04

15

12

 

 

 

 

 

03

8

6

 

 

 

 

 

02

4

3

 

 

 

 

 

01

2

2

 

00

1

1

Gain

 

0F

28 dB

 

 

 

 

 

 

0E

26 dB

 

 

 

 

 

 

0D

24 dB

 

 

 

 

 

 

0C

22 dB

 

 

 

 

 

 

0B

20 dB

 

 

 

 

 

 

0A

18 dB

 

 

 

 

 

09

16 dB

 

 

 

 

 

08

14 dB

 

 

 

 

 

07

12 dB

 

 

 

 

 

06

10 dB

 

 

 

 

 

05

8 dB

 

 

 

 

 

04

6 dB

 

 

 

 

 

03

4 dB

 

 

 

 

 

02

+2 dB

 

 

 

 

 

01

 

 

 

 

 

 

00

-3 dB

 

 

 

 

 

 

 

 

Iris

 

11

F1.6

 

 

 

 

 

 

10

F2

 

 

 

 

 

 

0F

F2.4

 

 

 

 

 

 

0E

F2.8

 

 

 

 

 

 

0D

F3.4

 

 

 

 

 

 

0C

F4

 

 

 

 

 

 

0B

F4.8

 

 

 

 

 

 

0A

F5.6

 

 

 

 

 

 

09

F6.8

 

 

 

 

 

 

08

F8

 

 

 

 

 

 

07

F9.6

 

 

 

 

 

 

06

F11

 

 

 

 

 

 

05

F14

 

 

04

F16

 

 

03

F19

 

 

02

F22

 

 

01

F28

 

 

00

CLOSE

 

 

 

 

Exposure control

 

 

IRIS

GAIN

Bright

1F

F1.6

28 dB

 

 

 

 

 

1E

F1.6

26 dB

 

 

 

 

 

1D

F1.6

24 dB

 

 

 

 

 

1C

F1.6

22 dB

 

 

 

 

 

1B

F1.6

20 dB

 

 

 

 

 

1A

F1.6

18 dB

 

 

 

 

 

19

F1.6

16 dB

 

 

 

 

 

18

F1.6

14 dB

 

 

 

 

 

17

F1.6

12 dB

 

 

 

 

 

16

F1.6

10 dB

 

 

 

 

 

15

F1.6

8 dB

 

 

 

 

 

14

F1.6

6 dB

 

 

 

 

 

13

F1.6

4 dB

 

 

 

 

 

12

F1.6

2 dB

 

 

 

 

 

11

F1.6

0

 

 

 

 

 

10

F2

0

 

 

 

 

 

0F

F2.4

0

 

 

 

 

 

0E

F2.8

0

 

 

 

 

 

0D

F3.4

0

 

 

 

 

 

0C

F4

0

 

 

 

 

 

0B

F4.8

0

 

 

 

 

 

0A

F5.6

0

 

09

F6.8

0

 

 

 

 

 

08

F8

0

 

 

 

 

 

07

F9.6

0

 

 

 

 

 

06

F11

0

 

 

 

 

 

05

F14

0

 

 

 

 

 

04

F16

0

 

 

 

 

 

03

F19

0

 

 

 

 

 

02

F22

0

 

 

 

 

 

01

F28

0

 

 

 

 

 

00

CLOSE

0

 

 

 

 

 

 

IRIS

GAIN

Exposure

0E

7

 

10.5 dB

Comp.

 

 

 

 

0D

6

 

9 dB

 

 

 

 

 

 

 

 

0C

5

 

7.5 dB

 

 

 

 

 

 

0B

4

 

6 dB

 

0A

3

 

4.5 dB

 

 

 

 

 

 

09

2

 

3 dB

 

 

 

 

 

 

08

1

 

1.5 dB

 

 

 

 

 

 

07

0

 

0 dB

 

 

 

 

 

 

06

-1

 

-1.5 dB

 

 

 

 

 

 

05

-2

 

-3 dB

 

 

 

 

 

 

04

-3

 

-4.5 dB

 

 

 

 

 

 

03

-4

 

-6 dB

 

 

 

 

 

 

02

-5

 

-7.5 dB

 

 

 

 

 

 

01

-6

 

-9 dB

 

 

 

 

 

 

00

-7

 

10.5 dB

 

 

 

 

 

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 21
Image 21
Polycom Ceiling DocCam user manual Visca Command Setting Values, Exposure control, Ntsc PAL, Close