10

Ceiling DocCam II — Installation

Configuring for remote controls

The Ceiling DocCam II can be programmed to work with the remotes listed below. DIP switches on the camera enclosure must be configured in order to work with these remotes. See Figure 2 on page 4 for exact location of DIP switches. Use the following diagram to program your Ceiling DocCam II correctly.

 

 

 

 

11

 

 

Ceiling DocCam II — Installation

 

 

 

 

 

 

 

Programming presets

Presets are used to program defined positions of the camera into a simple, one button preset. You can switch easily from a zoomed in position on a small document to a zoomed out position for documents such as blueprints. This saves the hassle of zooming in and out when presenting documents of a variety of sizes. You can program your ClearOne IR remote with six different presets labeled 0-5.

Note:These presets will only work with the ClearOne IR remote.

ClearOne Ceiling DocCam II (ONLY)

OFF

ON

1 2 3 4

1=Off 2=Off 3=Off 4=Off

PolyCom IPower 9000

OFF

ClearOne V-There

OFF

ON

1 2 3 4

1=On 2=On 3=On 4=On

PolyCom IPower 600 Set-top

PictureTel, and 900 Tower

OFF

Polycom VS-4000, ViewStation FX

ViewStation, VSX-7000

OFF

ON

1 2 3 4

1=On 2=Off 3=Off 4=Off

Tandberg

OFF

To program a preset

1.Zoom in or out to desired view.

2.Press the Set button once.The on-screen notification will indicate "Set number."

3.Press the selected preset button (0-5).

Note: If you want to reset a preset, just program a new preset using that same number. The new preset will override the old one.

PRESETS

0 1 2

3 4 5

SET

ON

1

2

3

4

1=Off 2=Off 3=On 4=On

ON

1

2

3

4

 

 

 

 

1=On

2=On

3=Off

4=Off

ON

1

2

3

4

 

 

 

 

1=Off

2=On

3=On

4=Off

Figure 12. Presets

Sony EVI-D100

OFF

ON

1

2

3

4

1=Off 2=Off 3=On 4=Off

Sony, PCS1 Set-top, PCS1600 Set-top,

PCS6000 Codec, PTZ Camera

OFF

ON

1 2 3 4

1=On 2=Off 3=On 4=Off

Aethra

OFF

ON

1

2

3

4

1=Off 2=Off 3=Off 4=On

Figure 11. DIP switch configurations

Note: For best performance of the VISCA™ (a trademark of Sony Corporation) commands, set DIP switches to the ClearOne configuration when the camera is connected to the control port of a codec.

Note: After changing the DIP switches, camera must be power cycled.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Page 7
Image 7
Polycom Ceiling DocCam user manual Configuring for remote controls, Programming presets, To program a preset