PROBLEM | CAUSE | CORRECTION |
Motor will not | Motor overload protection | Let motor cool off and |
run. | switch has tripped | overload switch will |
|
| automatically reset. |
| Tank pressure exceeds | Motor will start automatically |
| pressure switch | when tank pressure drops |
| pressure. | below |
|
| pressure switch. |
| Check valve stuck open. | Remove and clean, or replace. |
| Loose electrical | Check wiring connection |
| connections. | inside pressure switch and |
|
| terminal box area. |
| Possible defective motor | Have checked by a Trained |
| or starting capacitor. | Service Technician. |
| Paint spray on internal | Have checked by a Trained |
| motor parts. | Service Technician. Do not |
|
| operate the compressor in |
|
| the paint spray area. See |
|
| flammable vapor warning. |
| Pressure release valve on | Bleed the line by pushing the |
| pressure switch has not | lever on the pressure switch to |
| unloaded head pressure. | the "OFF" position; if the valve |
|
| does not open, replace switch. |
| Fuse blown, circuit breaker | 1. Check fuse box for blown |
| tripped. | fuse and replace as |
|
| necessary. Reset circuit |
|
| breaker. Do not use a |
|
| fuse or circuit breaker |
|
| with higher rating than |
|
| that specified for your |
|
| particular branch circuit. |
|
| 2. Check for proper fuse. You |
|
| should use a time delay |
|
| fuse. |
|
| 3. Check for low voltage |
|
| conditions and/or proper |
|
| extension cord. |
|
| 4. Disconnect the other |
|
| electrical appliances from |
|
| circuit or operate the |
|
| compressor on its own |
|
| branch circuit. |
|
|
|
A16759 | 24- ENG |