Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Drain Valve: The drain valve is located at the base of the air tank and is used
to drain condensation at the end of each use.
Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches
Check Valve
Pressure Release Valve: The pressure release valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches
Pressure
Release
Valve
Motor Overload Protector: This motor has a manual thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart:
1.Place the On/Auto/Off lever in the "Off" position.
2.Allow the motor to cool.
3.Depress the red reset button on the motor.
4.Place the On/Auto/Off lever in the "On/Auto"
Reset
postion toButton restart the
motor.
Air Intake Filter (not shown): This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See "Maintenance".
How to Use Your Unit
How to Stop:
1.Set the On/Auto/Off lever to "Off".
Before Starting
Risk of Unsafe Operation. Serious
damage may result if the following
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
1.Make sure the On/Auto/Off lever is in the "Off" position.
D27042 |