Porter-Cable CPF23400P instruction manual Problem Cause Correction

Models: CPF23400P

1 18
Download 18 pages 24.05 Kb
Page 14
Image 14

PROBLEM

CAUSE

CORRECTION

 

 

 

Pressure reading on

It is normal for “some”

If there is an excessive amount of

the regulated

pressure drop to occur.

pressure drop when the accessory

pressure gauge

 

is used, adjust the regulator

drops when an

 

following the instructions on page

accessory is used.

 

7.

 

 

NOTE: Adjust the regulated

 

 

pressure under flow conditions

 

 

(while accessory is being used).

 

 

 

Motor will not run or

Motor overload protection

Let motor cool off and overload

restart.

switch has tripped.

switch will automatically reset.

 

Tank pressure exceeds

Motor will start automatically when

 

pressure switch “cut-in”

tank pressure drops below “cut-in”

 

pressure.

pressure of pressure switch.

 

 

Check for proper gauge wire and

 

Wrong gauge wire or length of

cord length.

 

extension cord.

 

 

 

Remove and clean, or replace.

 

Check valve stuck open.

 

 

 

Check wiring connection inside

 

Loose electrical connections.

pressure switch and terminal box

 

 

area.

 

 

Contact an Authorized Warranty

 

Possible defective motor or

Service Center for inspection or

 

starting capacitor.

replacement, if necessary.

 

 

Have checked by an Authorized

 

Paint spray on internal motor

Warranty Service Center. Do not

 

parts.

operate the compressor in the paint

 

 

spray area. See flammable vapor

 

 

warning.

 

Fuse blown, circuit breaker

1. Check fuse box for blown fuse

 

and replace, if necessary. Reset

 

tripped.

circuit breaker. Do not use a

 

 

fuse or circuit breaker with

 

 

higher rating than that specified

 

 

for your particular branch circuit.

 

 

2. Check for proper fuse; only time

 

 

delay fuses are acceptable.

 

 

3. Check for low voltage

 

 

conditions and/or proper

 

 

extension cord.

 

 

4. Disconnect the other electrical

 

 

appliances from circuit or

 

 

operate the compressor on its

 

 

own branch circuit.

 

Pressure release valve on

Bleed the line by pushing the lever

 

pressure switch has not

on the pressure switch to the “off”

 

unloaded head pressure.

position; if the valve does not open,

 

 

replace it.

 

 

 

14-ENG

Page 14
Image 14