5.4 DISCHARGE.
NOTE: For battery voltages greater than 32V, the discharge current is automatically
limited to 30A. A current fault condition will result if more than 30A is programmed.
5.4.1. ANALYSIS (AUTO CUT-OFF):
5.4.1.1. The battery is discharged at the selected rate for a preset time.
5.4.1.2. Discharge is automatically terminated (cycle end), at the end of the
time selected or if the battery voltage reaches the equivalent of 1
VOLT/cell (capacity failure), as determined by the number of cells
programmed, or it is terminated as a fault, if:
The actual discharge current differs from the programmed value by
more than 1 AMP (current fault).
Overheating of the transistor heat sinks is detected (overheat fault).
NOTE: Discharge operation can be terminated at any time by
depressing the (green) reset button.
5.4.2. DEEP CYCLE (FULL DISCHARGE):
5.4.2.1. The battery is discharged at the selected rate for a preset time.
5.4.2.2. Discharge is automatically terminated (cycle end) at the end of the time
selected, or as a fault, if:
The actual discharge current differs from the programmed value by
more than 1 AMP (current fault). NOTE: Undercurrent fault
monitoring is disabled at battery voltages below 2V.
Overheating of the transistor heat sinks is detected (overheat fault).