Operator Manual, Supercharger 60 | R3.0 |
6.3.4.RUN
6.3.4.1.Start the
6.3.4.2.The charge will terminate automatically (CYCLE END) when the TOTAL TIME selected is reached.
6.3.4.3.The charge will terminate as a FAULT if the MONITOR CIRCUIT detects that:
•Battery temperature exceeds 45oC/113oF (BATTERY OVERTEMP FAULT).
•The actual charge current deviates from the programmed value by more than 1A (CURRENT FAULT).
6.4PEAK VOLTAGE CHARGE:
6.4.1.Nominal Battery Voltage
6.4.1.1.Enter the nominal battery voltage using the Cell selector (see chart on page 19).
6.4.1.2.Select transfer from Main to Topping on Peak Voltage or stop on Peak Voltage.
6.4.2.Charge Currents
6.4.2.1.Program the Main and Topping Charge currents as required.
6.4.3.Time
6.4.3.1.Program the Main and Total Time selectors to allow the battery to reach the required charge level (consult battery manufacturers specifications).
6.4.3.2.Verify that the Timer Speed is consistent with the required elapsed time.
6.4.4.RUN
6.4.4.1.Start the
6.4.4.2.The charge will terminate automatically (CYCLE END) when the TOTAL TIME selected is reached.
6.4.4.3.The charge will terminate as a FAULT if the MONITOR CIRCUIT detects that:
•Battery temperature exceeds 45oC/113oF (BATTERY OVERTEMP FAULT).
•The actual charge current deviates from the programmed value by more than 1A (CURRENT FAULT).