Premier Mounts LPFM1532 Determining the Mounting Hardware, Universal Spacers Installation

Models: LPFM1532

1 11
Download 11 pages 23.03 Kb
Page 6
Image 6

LPFM1532

Determining the Mounting Hardware

Step 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel. Step 2. Using a pencil, mark the depth of the thread insert on the thread depth indicator (Figure 2).

Step 3. Compare and verify the depth of the remaining thread inserts. Step 4. Locate the correct diameter screw for the thread insert.

Step 5. Compare your thread depth indicator marking to the screw length.

If your selected screw is longer than

the marking on the thread depth indicator, do not use this screw. The screw length must not bypass the

marking. If so, select another screw size (Figure 2 and 3) until you find the

screw the comes closest to your mark without going past the marking.

When using the universal spacers in the installation, make sure to account for the appropriate spacing depth when measuring with the thread depth indicator. Using the universal spacers will change the overall length of the hardware used.

Figure 1

Inverted Flat Panel Display

Marking the Depth

Thread Insert

Thread Depth

Indicator

Screw

Marking

Screw

Marking

 

 

 

Thread Depth

Thread Depth

Indicator

Indicator

Figure 2

Figure 3

 

Universal Spacers Installation

You may not need to use any spacers for your particular flat panel.

The universal spacer may be stacked five (5) high, for a total stacking height of 1-1/4”. The universal spacers must be stacked in the direction shown above. The universal spacers must be placed between the mounting bracket and the flat panel.

The universal spacer will fit M4, M5, M6 and M8 screws sizes.

Page 6

Installation Instructions

Page 6
Image 6
Premier Mounts LPFM1532 installation instructions Determining the Mounting Hardware, Universal Spacers Installation