V I I . O P E R A T I O N
Remote Plus Error Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with your power chair’s electrical system. If any of the battery condition meter lights are flashing rapidly, the controller may be indicating an error. Error codes are displayed as a number of flashing lights. For instance, if the first light is flashing rapidly, the battery voltage is nearly depleted. The table below identifies the individual error codes, probable causes, and possible solutions. If you get one of these error codes, contact your authorized Pride Provider.
FLASHING LIGHTS | DIAGNOSIS | SOLUTION |
10 | High Battery Voltage | Check batteries. |
|
|
|
9 | Solenoid Brake Fault | Check motor/brake wiring. |
|
|
|
8 | Possible Controller Fault | See authorized Pride Provider. |
|
|
|
7 | Possible Joystick Fault | See authorized Pride Provider. |
|
|
|
6 | Inhibit Active | Unplug charger. Check connections. |
|
|
|
5 | Right Motor Wiring Fault | Check right motor wiring. |
|
|
|
4 | Right Motor Disconnected | Check right motor wiring. |
|
|
|
3 | Left Motor Wiring Fault | Check left motor wiring. |
|
|
|
2 | Left Motor Disconnected | Check left motor wiring. |
|
|
|
1 | Low Battery Voltage | Check batteries/battery wiring. |
|
|
|
42 | www.pridemobility.com | Jazzy 1103 Ultra |