Basic Operation Instructions

19

 

 

Error Code

Probable Cause

Possible Solution

1

Possible stall timeout or user error

Release the joystick.

2

Battery Fault

Check the batteries and cables. Try

 

 

to charge the batteries. The batteries

 

 

may need to be replaced.

3

Left Motor Fault

Check the left motor, connections,

 

 

and cabling.

4

Right Motor Fault

Check the right motor, connections,

 

 

and cabling.

5

Left Park Brake Fault

Check the left park brake, connections,

 

 

and cabling.

6

Right Park Brake Fault

Check the right park brake, connections,

 

 

and cabling.

7

Dynamic Controller Module

Check the communications connections

 

Fault

and wiring.

8

Dynamic Controller Power

Check the communications connections

 

Module Fault

and wiring.

9

Dynamic Controller

Check the communications connections

 

Communications Fault

and wiring.

10

Unknown Fault

Contact your authorized Pride Provider.

11

Incompatible Controller Fault

Contact your authorized Pride Provider.

CARE AND MAINTENANCE

Refer to your power chair owner’s manual for proper cleaning and disposal instructions.

WARRANTY

For two (2) years from the date of purchase, Pride will repair or replace at our option to the original purchaser, free of charge, the controller or any of its components found upon examination by an authorized representative of Pride to be defective in material and/or workmanship.

www.pridemobility.com

Dynamic Controller

Page 19
Image 19
Pride Mobility INFMANU3676 manual Care and Maintenance Warranty, Error Code Probable Cause Possible Solution