V I I . O P E R A T I O N

NOTE: The battery gauge will flash the “locked” sequence. 1 LED will flash on and then off. 2 LEDs will flash on and then off. This sequence will continue until all five LEDs flash on and then off. The sequence will continue until the power is turned off or until the controller is unlocked.

To unlock the controller:

1.Press the on/off button to turn on the controller. The battery condition meter will flash the “locked” sequence.

2.Move the joystick to the full forward position until it beeps.

3.Move the joystick to the full rearward position until it beeps.

4.Release the joystick. There will be one long beep. The controller system is now unlocked.

Sleep Mode

The power chair controller features a sleep mode. Sleep mode is a built-in circuit that will automatically shut off the main power if the joystick is not moved in any direction for a period of time. This time factor is programmed into the controller. To restore power and continue, push any button on the control panel.

Fault Codes

The battery condition meter will flash fault codes when the controller system detects an abnormal condition is the electrical system. All of the battery condition meter LEDs will flash a number of times quickly, then pause, then flash again. The battery condition meter will continue to flash the fault codes until the problem is fixed. The table below identifies the individual fault codes. If any of these fault codes persist, contact your authorized Pride Provider.

Fault Code

Probable Cause(s)

Possible Solution

1

Flash

The batteries need charging.

Check the battery connections. If the battery

 

 

There is a bad connection to the batteries.

connections are good, then try charging the

 

 

 

batteries.

 

 

 

 

2

Flashes

There is a bad connection on the left motor.

Check the left motor connections and wiring

 

 

 

harnesses.

 

 

 

 

3

Flashes

The left motor has a short to a battery connection.

Contact your authorized Pride Provider.

 

 

 

 

4

Flashes

There is a bad connection on the right motor.

Check the right motor connections and wiring

 

 

 

harnesses.

 

 

 

 

5

Flashes

The right motor has a short to a battery connection.

Contact your authorized Pride Provider.

 

 

 

Rippling LEDs

The charge inhibit has been activated.

Make sure that the battery charger is not

 

 

 

connected to the power base.

 

 

 

 

7

Flashes

There is a joystick fault.

Make sure the joystick is in the center position

 

 

 

and then power off and on again.

 

 

 

 

8

Flashes

There is a control system fault.

Check power module and joystick module

 

 

 

connections and wiring.

 

 

 

 

9

Flashes

The park brakes have a bad connection.

Check the left and right motor connections and

 

 

 

wiring.

 

 

 

10 Flashes

An excessive voltage has been applied to

Check the battery connections.

 

 

the control system.

 

 

 

 

 

Jet 3 Ultra

www.pridemobility.com

33

Page 33
Image 33
Pride Mobility JET 3 To unlock the controller, Sleep Mode, Fault Codes, Fault Code Probable Causes Possible Solution