FRESH AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a

confined space

or

unusually

tight construction

unless

provisions

are

provided

for

adequate

combustion

and

ventilation

air .

Read

the

f o l l o w i n g

i n s t r u c t i o n s

t o

insure proper fresh air for this

and other fuel-burning appliances in your home.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction. you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6×10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around win- dow and door frames, between sole

plates

and floors, between

wall-

ceiling

joints, between wall panels, at

penetrations for plumbing, electrical,

and gas lines, and at other

openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air from Outdoors, pages 5 and 6.

If your home does not meet all of the three criteria above see Determining Fresh-Air Flow for Heater Location, page 4, 5.

Confined and

Unconfined Space

The National Fuel Gas Code ANS

Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour ( 4 . 8 m 3 p e r k w ) o f t h e aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4 . 8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with

t h e s p a c e

i n w h i c h t h e

appliances are

installed*, through

openings not furnished with doors, are considered a part of the

unconfined

space.

 

 

 

 

This

heater shall

not

be installed

in a

confined

space

or

unusually

t i g h t c o n s t r u c t i o n

u n l e s s

provisions

are

provided

for

adequate

 

combustion

and

ventilation

air.

 

 

 

 

 

*

A d j o i n i n g

r o o m s

a r e

communicating only

if

there

are

d o o r l e s s p a s s a g e w a y s

o r

ventilation

grills between

them.

 

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if you have a Confined or Unconfined Space*

 

 

Use this worksheet to determine if you have a confined or unconfined space.

 

Space: Includes the room in which

you will install heater plus any

adjoining rooms with doorless

passageways

or ventilation grills between

the rooms.

 

×

 

 

 

1. Determine the volume of

 

 

×

width

height).

 

 

the space (length

 

 

 

Length×Width×Height=

 

 

 

cu.ft. (volume of space)

 

 

 

 

×

 

×

 

 

 

 

Example: Space size 18ft (length)

 

16ft( width) 8ft. (ceiling height)=2304cu. ft. (volume of space)

 

If additional ventilation to adjoining room is

supplied with grills

or openings, add the volume

of these

rooms to the total volume of the space.

 

 

 

 

 

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support. (volume of space)÷ 50 cu. ft.=(Maximum Btu/Hr the space can support)

Example: 2304 cu. ft. (volume of space)÷ 50 cu.ft.=46.1 or 46,100(maximum Btu/Hr the space can support)

 

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined

space or if the building is of unusually tight construction, provide

adequate combustion

and ventilation air by one

of

the methods described in the National Fuel

Gas Code, ANS

Z223.1, Section 5.3

or

applicable local codes.

 

 

 

 

 

 

4

Page 4
Image 4
Procom ML100HPA, ML060HPA, ML100TPA Fresh AIR for Combustion and Ventilation, Providing Adequate Ventilation

ML060HPA, ML100TPA, ML100HPA specifications

Procom's ML100TPA, ML100HPA, and ML060HPA are cutting-edge amplifiers designed to enhance communication capabilities across various applications. These models are particularly popular in the fields of radio and communication technology, providing reliable performance and superior signal quality.

The ML100TPA is a high-performance, compact transmitter amplifier. It boasts an impressive power output of up to 100 watts, making it suitable for long-range communications. One of its standout features is its wide frequency range, accommodating multiple bands, which allows users to switch between applications seamlessly. The built-in thermal management system ensures stable operation even under heavy loads, preventing overheating and enhancing durability.

The ML100HPA is another powerful offering from Procom, specifically tailored for high-power applications. With a power output similar to the ML100TPA, this amplifier delivers robust performance while maintaining a compact form factor. It includes advanced features such as automatic gain control, ensuring consistent output levels regardless of input variations, which is essential for maintaining signal integrity. Additionally, the ML100HPA integrates an innovative protection circuit that safeguards against mismatches and overloads, enhancing reliability in demanding environments.

On the other hand, the ML060HPA is designed for applications where size and weight are critical considerations without compromising on performance. This model offers a power output of 60 watts, making it ideal for portable setups and mobile operations. Despite its smaller size, the ML060HPA does not skimp on features, including a high-efficiency design that maximizes battery life in mobile applications. It is also equipped with advanced filtering technologies to minimize harmonic distortion and maintain clear communication.

All three models leverage Procom's proprietary technologies, ensuring that they meet the stringent requirements of modern communication systems. They are built with high-quality components to ensure longevity and consistent performance in various environments, from urban settings to remote locations. Moreover, each model is user-friendly, with easy setup and configuration options, making them accessible for both novice and seasoned users.

In summary, the Procom ML100TPA, ML100HPA, and ML060HPA amplifiers represent the pinnacle of communication technology, each offering unique features tailored to specific user needs. Their combination of power, efficiency, and advanced technology makes them invaluable tools for enhancing communication capabilities across a wide range of applications. Whether for broadcasting, emergency communications, or mobile operations, Procom's amplifiers provide the quality and reliability needed to keep users connected.