INFRARED VENT-FREE

PROPANE/LP GAS

SPACE HEATER

OWNERS OPERATION AND INSTALLATION MANUAL

ML060HPA ML100HPA ML100TPA

Do not store, or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a q u a l i f i e d i n s t a l l e r , s e r v i c e a g e n c y o r g a s supplier.

Table of Contents

 

Important Safety Information

2

Product Features

3

Proper Ventilation & Fresh Air

4

Installation

6

Operating Your Heater

10

Cleaning & Maintenance

13

Trouble Shooting

14

Specifications

17

Parts List

19

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

WARNING: This is an unvented gas- fired heater. It uses air (oxygen) f r o m t h e r o o m i n w h i c h i t i s installed. Provi- sions for adequate combustion and ventila- tion air must be provided . Refer to Air For Combustion and Ventilation section on page 4 of this manual.

Continental Appliance Inc.

5 Musick

4600 Highlands

Irvine

Parkway S.E. Suite# D/E

CA 92618

Smyrna GA 30080

WA R N I N G : Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier.

This appliance may be installed in an aftermar- ket* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Refer to page 3.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

Installer: Please leave these instructions with the consumer.

Consumer: Please retain these instructions for future use.

TOLL-FREE NUMBER: 1-877-886-5989

Page 1
Image 1
Procom installation manual OWNER’S Operation and Installation Manual, ML060HPA ML100HPA ML100TPA

ML060HPA, ML100TPA, ML100HPA specifications

Procom's ML100TPA, ML100HPA, and ML060HPA are cutting-edge amplifiers designed to enhance communication capabilities across various applications. These models are particularly popular in the fields of radio and communication technology, providing reliable performance and superior signal quality.

The ML100TPA is a high-performance, compact transmitter amplifier. It boasts an impressive power output of up to 100 watts, making it suitable for long-range communications. One of its standout features is its wide frequency range, accommodating multiple bands, which allows users to switch between applications seamlessly. The built-in thermal management system ensures stable operation even under heavy loads, preventing overheating and enhancing durability.

The ML100HPA is another powerful offering from Procom, specifically tailored for high-power applications. With a power output similar to the ML100TPA, this amplifier delivers robust performance while maintaining a compact form factor. It includes advanced features such as automatic gain control, ensuring consistent output levels regardless of input variations, which is essential for maintaining signal integrity. Additionally, the ML100HPA integrates an innovative protection circuit that safeguards against mismatches and overloads, enhancing reliability in demanding environments.

On the other hand, the ML060HPA is designed for applications where size and weight are critical considerations without compromising on performance. This model offers a power output of 60 watts, making it ideal for portable setups and mobile operations. Despite its smaller size, the ML060HPA does not skimp on features, including a high-efficiency design that maximizes battery life in mobile applications. It is also equipped with advanced filtering technologies to minimize harmonic distortion and maintain clear communication.

All three models leverage Procom's proprietary technologies, ensuring that they meet the stringent requirements of modern communication systems. They are built with high-quality components to ensure longevity and consistent performance in various environments, from urban settings to remote locations. Moreover, each model is user-friendly, with easy setup and configuration options, making them accessible for both novice and seasoned users.

In summary, the Procom ML100TPA, ML100HPA, and ML060HPA amplifiers represent the pinnacle of communication technology, each offering unique features tailored to specific user needs. Their combination of power, efficiency, and advanced technology makes them invaluable tools for enhancing communication capabilities across a wide range of applications. Whether for broadcasting, emergency communications, or mobile operations, Procom's amplifiers provide the quality and reliability needed to keep users connected.