TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

 

POSSIBLE CAUSE

 

 

REMEDY

 

 

 

 

 

 

 

 

 

Heater produces unwanted odors.

1.

Heater

is burning vapors

from

1.

Ventilate room. Stop using odor

 

 

paint,

hair

spray,

glues,

etc.

 

causing products while heater

 

 

(See

IMPORTANT

statement

 

is running.

 

 

 

 

 

above).

 

 

 

 

2.

Locate and correct all leaks(see

 

2 . Gas

leak .

See

Warning

 

Checking Gas Connections,

 

 

Statement at top of page.

 

 

page 10).

 

 

 

 

3.

Low fuel supply.

 

 

3.

Refill supply tank.

 

 

 

 

 

 

 

 

 

 

Heater shuts off in use (ODS operates).

1.

Not enough fresh air is available.

1.

Open window

and/or

door

for

 

 

 

 

 

 

 

 

ventilation.

 

 

 

 

2.

Low line pressure.

 

 

2.

Contact local

propane/LP

gas

 

 

 

 

 

 

 

 

company.

 

 

 

 

3.

ODS/pilot is

partially clogged

3.

Clean ODS/pilot (see

Cleaning

 

 

 

 

 

 

 

 

page 13).

 

 

 

Gas odor exists even when control knob is in OFF position.

1. Gas leak. See Warning

1.

Locate and correct all leaks(see

Statement at top of page.

 

Checking Gas

Connections,

 

 

page 10).

 

2. Control valve defective.

2.

Replace control

valve.

Gas odor during combustion.

1.

Foreign matter between

control

1.

Take

apart

gas tubing

and

 

 

valve and burner.

 

 

remove foreign matter.

 

 

2.

Gas leak. See Warnin

State-

2.

Locate

and

correct all

leaks

 

 

ment at top of page.

 

 

(see

 

Checking

Gas

 

 

 

 

 

Connections, page 10).

 

 

 

 

 

 

Moisture/condensation noticed on

1.

Not enough combustion/ventilation

1.

Refer to Air for Combustion and

windows.

 

air.

 

 

Ventilation requirements ,page

 

 

 

 

 

4.

 

 

 

1 6