TROUBLESHOOTING
Continued
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM |
| POSSIBLE CAUSE |
|
| REMEDY |
|
| ||||
|
|
|
|
|
|
| |||||
Heater produces unwanted odors. | 1. | Heater | is burning vapors | from | 1. | Ventilate room. Stop using odor | |||||
|
| paint, | hair | spray, | glues, | etc. |
| causing products while heater | |||
|
| (See | IMPORTANT | statement |
| is running. |
|
|
| ||
|
| above). |
|
|
|
| 2. | Locate and correct all leaks(see | |||
| 2 . Gas | leak . | See | Warning |
| Checking Gas Connections, | |||||
|
| Statement at top of page. |
|
| page 10). |
|
|
| |||
| 3. | Low fuel supply. |
|
| 3. | Refill supply tank. |
|
| |||
|
|
|
|
|
|
|
| ||||
Heater shuts off in use (ODS operates). | 1. | Not enough fresh air is available. | 1. | Open window | and/or | door | for | ||||
|
|
|
|
|
|
|
| ventilation. |
|
|
|
| 2. | Low line pressure. |
|
| 2. | Contact local | propane/LP | gas | |||
|
|
|
|
|
|
|
| company. |
|
|
|
| 3. | ODS/pilot is | partially clogged | 3. | Clean ODS/pilot (see | Cleaning | |||||
|
|
|
|
|
|
|
| page 13). |
|
|
|
Gas odor exists even when control knob is in OFF position.
1. Gas leak. See Warning | 1. | Locate and correct all leaks(see | |
Statement at top of page. |
| Checking Gas | Connections, |
|
| page 10). |
|
2. Control valve defective. | 2. | Replace control | valve. |
Gas odor during combustion. | 1. | Foreign matter between | control | 1. | Take | apart | gas tubing | and |
|
| valve and burner. |
|
| remove foreign matter. |
| ||
| 2. | Gas leak. See Warnin | State- | 2. | Locate | and | correct all | leaks |
|
| ment at top of page. |
|
| (see |
| Checking | Gas |
|
|
|
|
| Connections, page 10). |
| ||
|
|
|
|
| ||||
Moisture/condensation noticed on | 1. | Not enough combustion/ventilation | 1. | Refer to Air for Combustion and | ||||
windows. |
| air. |
|
| Ventilation requirements ,page | |||
|
|
|
|
| 4. |
|
|
|