6.Press a CD Holder (85) into each side of the Upright Base (97).

If the Wheels (not shown) are touching the floor, or if the treadmill rocks slightly, see HOW TO LEVEL THE

TREADMILL on page 20.

If you wish to adjust the height of the Uprights (80, 84), go to step 7. If the Uprights are at the desired height, tighten the four Upright Bolts (86) and go to step 8.

7.Note: The Uprights (80, 84) can be attached at three dif- ferent heights. The Uprights are preattached in the mid- dle position. Adjusting the Uprights requires two persons.

While a second person holds the Console Base (101) and the Uprights (80, 84), loosen the four Upright Bolts (86). Then, remove the two Upright Bolts and Upright Star Washers (127) from the Right Upright (80). Raise or lower the Right Upright to the desired height, being careful not

to damage the Wire Harness (74). If the Upright Spacer

(79)falls, press it back onto the Upright Base (97). Loosely thread the two Upright Bolts and Upright Star Washers back into the Right Upright and the Upright Base.

Adjust the Left Upright (84) in the same way. (Note: There

are no wires in the Left Upright.) Make sure that both

Uprights are at the same height. Lift the Walking Platform (13) and make sure it is centered between

the Uprights. Retighten all four Upright Bolts (86).

6

 

84

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

85

86

 

97

80

 

 

 

 

 

 

 

 

 

 

 

 

97

 

 

 

86

 

7

 

 

 

 

84

 

 

 

 

 

 

 

101

 

127

 

79

 

 

 

 

 

 

 

 

 

 

80

86

 

 

 

 

 

13

 

74

79

 

 

 

 

 

 

97

 

 

127

 

 

 

 

 

 

 

86

 

 

8. Make sure that all parts are properly tightened before you use the treadmill.Note: Extra hardware may

be included. Keep the included allen wrenches in a secure place. The large allen wrench is used to adjust the walking belt (see page 23). To protect the floor or carpet, place a mat under the treadmill.

If you purchase the optional chest pulse sensor (see page 20), follow the steps below to install the receiver included with the chest pulse sensor.

1. Make sure that the power cord is unplugged.

Remove

the indicated Screw (108) and the Access Door (122).

 

2.Remove the paper from the adhesive pad on the back of the receiver (A). Hold the receiver so the small cylin- der is near the lower edge of the receiver and facing

the Console (107) as shown.

Firmly press the receiver

onto the indicated corner of the Access Door (122).

Connect the wire on the receiver to the indicated wire ex-

tending from the Console.

 

3. Make sure that no wires are pinched.

Reattach the

Access Door (122) with the Screw (108). Note: The wires included with the receiver may be discarded.

107

Wire

A

Wire

Cylinder

122

108

7

Page 7
Image 7
ProForm 831.293201 user manual Uprights. Retighten all four Upright Bolts, Console 107 as shown