Profoto Pro-7 manual Changing Battery, Connecting Lamp Heads

Models: Pro-7

1 43
Download 43 pages 45.64 Kb
Page 36
Image 36

[1]

[2]

[6]

Changing Battery

By putting the two handles at the bottom together the battery cassette is released and the battery can easily be pulled out. A new battery is pushed all the way into the generator and is locked by directing the handles away from each other. When changing the battery it must be mounted in a battery cassette by an authorised service station. If the battery is not pur- chased at Profoto a Hitachi HV 12 -12 unit must be used.

Connecting Lamp Heads

One or two lamp heads can be connected to the lamp head sockets A & B [1]. When connecting the lamp head plug, align the dots on the plug with the white dot on the generator panel. Secure by turning the locking ring on the plug clockwise.

Energy Control

The energy output is regulated over seven f:stops. The energy can partly be adjusted with the control MASTER [13] in 1/6 f:stop increments, from 1/1 down to 1/16 of the total energy (equivalent to five f:stops) partly with the SYM/ASYM switch [2] through one or two lamp heads.

One lamp head: The total energy chosen is obtained if the lamp head is connected to A and the SYM/ASYM switch is at A 1/1(1/2), B 1/2. The lamp head can be connected to socket A or B. If the lamp head is connected to A the total energy is obtained chosen with the control MASTER [13]. If the lamp

36

Page 36
Image 36
Profoto Pro-7 manual Changing Battery, Connecting Lamp Heads